From 186c309e54c57ee1a9e12b1064cfccc39fefd3ef Mon Sep 17 00:00:00 2001 From: =?UTF-8?q?=E2=80=9CGlenn?= <glenn@ascentsoftware.eu> Date: Tue, 22 Mar 2016 08:12:33 +0100 Subject: [PATCH] Update AAUXTestVehicles files --- .../24t Coach/24t Coach_AAux_Zero.vecto | 2 +- .../24t Coach/AdvAuxTest.aaux | 9 +-- .../24t Coach/AdvAuxTest_Zero.aaux | 3 +- .../AAUXTestVehicles/24t Coach/Zero.acmp | 52 ++++++------- .../24t Coach/testHVACssm.AHSM | 70 ++++++++--------- .../24t Coach/testHVACssm_AllTechs.AHSM | 78 +++++++++---------- 6 files changed, 107 insertions(+), 107 deletions(-) diff --git a/Generic Vehicles/AAUXTestVehicles/24t Coach/24t Coach_AAux_Zero.vecto b/Generic Vehicles/AAUXTestVehicles/24t Coach/24t Coach_AAux_Zero.vecto index 41f74c10c2..3f0945ad18 100644 --- a/Generic Vehicles/AAUXTestVehicles/24t Coach/24t Coach_AAux_Zero.vecto +++ b/Generic Vehicles/AAUXTestVehicles/24t Coach/24t Coach_AAux_Zero.vecto @@ -1,7 +1,7 @@ { "Header": { "CreatedBy": "Nikolas.Hill@ricardo.com (59753f44-cf9b-4a64-b131-7b334ff25883)", - "Date": "19/01/2016 12:53:57", + "Date": "18/02/2016 15:10:02", "AppVersion": "2.0.4-AUX.Alpha.3", "FileVersion": 2 }, diff --git a/Generic Vehicles/AAUXTestVehicles/24t Coach/AdvAuxTest.aaux b/Generic Vehicles/AAUXTestVehicles/24t Coach/AdvAuxTest.aaux index 9149c5b2a0..092f8411f4 100644 --- a/Generic Vehicles/AAUXTestVehicles/24t Coach/AdvAuxTest.aaux +++ b/Generic Vehicles/AAUXTestVehicles/24t Coach/AdvAuxTest.aaux @@ -11,7 +11,7 @@ "ElectricalUserInputsConfig": { "$type": "VectoAuxiliaries.Electrics.ElectricsUserInputsConfig, BusAuxiliaries", "PowerNetVoltage": 28.3, - "AlternatorMap": "", + "AlternatorMap": "Default_2Alt.AALT", "AlternatorGearEfficiency": 0.92, "ElectricalConsumers": { "$type": "VectoAuxiliaries.Electrics.ElectricalConsumerList, BusAuxiliaries", @@ -264,7 +264,7 @@ "AirSuspensionControl": "Mechanically", "Doors": "Pneumatic", "KneelingHeightMillimeters": 70.0, - "ActuationsMap": "testPneumaticActuationsMap.APAC", + "ActuationsMap": "testPneumaticActuationsMap.apac", "RetarderBrake": true, "SmartAirCompression": false, "SmartRegeneration": false @@ -286,7 +286,7 @@ }, "HvacUserInputsConfig": { "$type": "VectoAuxiliaries.Hvac.HVACUserInputsConfig, BusAuxiliaries", - "SSMFilePath": "", + "SSMFilePath": "testHVACssm.AHSM", "BusDatabasePath": "BusDatabase.abdb", "SSMDisabled": false }, @@ -311,7 +311,6 @@ "EngineIdleSpeed": 0.0, "PneumaticOverrunUtilisation": 0.0, "StoredEnergyEfficiency": 0.0, - "RunningCalc": false, - "Internal_Engine_Power": 0.0 + "RunningCalc": false } } \ No newline at end of file diff --git a/Generic Vehicles/AAUXTestVehicles/24t Coach/AdvAuxTest_Zero.aaux b/Generic Vehicles/AAUXTestVehicles/24t Coach/AdvAuxTest_Zero.aaux index cf2e413006..42014bbde6 100644 --- a/Generic Vehicles/AAUXTestVehicles/24t Coach/AdvAuxTest_Zero.aaux +++ b/Generic Vehicles/AAUXTestVehicles/24t Coach/AdvAuxTest_Zero.aaux @@ -286,7 +286,7 @@ "AdBlueDosing": "Electric", "AirSuspensionControl": "Mechanically", "Doors": "Electric", - "KneelingHeightMillimeters": 1E-05, + "KneelingHeightMillimeters": 0.0, "ActuationsMap": "ZeroPneumaticActuationsMap.APAC", "RetarderBrake": true, "SmartAirCompression": false, @@ -318,6 +318,7 @@ "ClutchEngaged": false, "EngineDrivelinePower": 0.0, "EngineDrivelineTorque": 0.0, + "EngineInertia": 0.0, "EngineMotoringPower": 0.0, "EngineSpeed": 2000, "SmartElectrics": false, diff --git a/Generic Vehicles/AAUXTestVehicles/24t Coach/Zero.acmp b/Generic Vehicles/AAUXTestVehicles/24t Coach/Zero.acmp index c5c31bc2cf..f7c4eed8fb 100644 --- a/Generic Vehicles/AAUXTestVehicles/24t Coach/Zero.acmp +++ b/Generic Vehicles/AAUXTestVehicles/24t Coach/Zero.acmp @@ -1,27 +1,27 @@ RPM,FlowRate [l/min],Power [on] [W],Power [off] [W] -500,198,0.01,0.01 -600,239,0.01,0.01 -700,280,0.01,0.01 -800,322,0.01,0.01 -900,363,0.01,0.01 -1000,405,0.01,0.01 -1100,446,0.01,0.01 -1200,487,0.01,0.01 -1300,528,0.01,0.01 -1400,568,0.01,0.01 -1500,605,0.01,0.01 -1600,640,0.01,0.01 -1700,673,0.01,0.01 -1800,706,0.01,0.01 -1900,736,0.01,0.01 -2000,764,0.01,0.01 -2100,791,0.01,0.01 -2200,812,0.01,0.01 -2300,832,0.01,0.01 -2400,851,0.01,0.01 -2500,870,0.01,0.01 -2600,887,0.01,0.01 -2700,904,0.01,0.01 -2800,920,0.01,0.01 -2900,936,0.01,0.01 -3000,951,0.01,0.01 +500,198,0.0,0.00 +600,239,0.0,0.0 +700,280,0.0,0.0 +800,322,0.0,0.0 +900,363,0.0,0.0 +1000,405,0.0,0.0 +1100,446,0.0,0.0 +1200,487,0.0,0.0 +1300,528,0.0,0.0 +1400,568,0.0,0.0 +1500,605,0.0,0.0 +1600,640,0.0,0.0 +1700,673,0.0,0.0 +1800,706,0.0,0.0 +1900,736,0.0,0.0 +2000,764,0.0,0.0 +2100,791,0.0,0.0 +2200,812,0.0,0.0 +2300,832,0.0,0.0 +2400,851,0.0,0.0 +2500,870,0.0,0.0 +2600,887,0.0,0.0 +2700,904,0.0,0.0 +2800,920,0.0,0.0 +2900,936,0.0,0.0 +3000,951,0.0,0.0 diff --git a/Generic Vehicles/AAUXTestVehicles/24t Coach/testHVACssm.AHSM b/Generic Vehicles/AAUXTestVehicles/24t Coach/testHVACssm.AHSM index 1b75fdccf6..5ff264ba04 100644 --- a/Generic Vehicles/AAUXTestVehicles/24t Coach/testHVACssm.AHSM +++ b/Generic Vehicles/AAUXTestVehicles/24t Coach/testHVACssm.AHSM @@ -45,7 +45,7 @@ }, "EC_EnviromentalConditions_BatchFile": "DefaultClimatic.aenv", "EC_EnviromentalConditions_BatchEnabled": true, - "AC_CompressorType": "2-stage", + "AC_CompressorType": "2-Stage", "AC_CompressorTypeDerived": "Mechanical", "AC_CompressorCapacitykW": 18.0, "AC_COP": 3.5, @@ -57,8 +57,8 @@ "VEN_VentilationDuringCooling": "high", "AH_EngineWasteHeatkW": 0.0, "AH_FuelFiredHeaterkW": 30.0, - "AH_FuelEnergyToHeatToCoolant": 0.2, - "AH_CoolantHeatTransferredToAirCabinHeater": 0.75 + "AH_FuelEnergyToHeatToCoolant": 0.0, + "AH_CoolantHeatTransferredToAirCabinHeater": 0.0 }, "TechList": { "$type": "VectoAuxiliaries.Hvac.SSMTechList, BusAuxiliaries", @@ -110,7 +110,7 @@ }, "EC_EnviromentalConditions_BatchFile": "DefaultClimatic.aenv", "EC_EnviromentalConditions_BatchEnabled": true, - "AC_CompressorType": "2-stage", + "AC_CompressorType": "2-Stage", "AC_CompressorTypeDerived": "Mechanical", "AC_CompressorCapacitykW": 18.0, "AC_COP": 3.5, @@ -122,10 +122,10 @@ "VEN_VentilationDuringCooling": "high", "AH_EngineWasteHeatkW": 0.0, "AH_FuelFiredHeaterkW": 30.0, - "AH_FuelEnergyToHeatToCoolant": 0.2, - "AH_CoolantHeatTransferredToAirCabinHeater": 0.75 + "AH_FuelEnergyToHeatToCoolant": 0.0, + "AH_CoolantHeatTransferredToAirCabinHeater": 0.0 }, - "Units": "fraction", + "Units": "Fraction", "Category": "Cooling", "BenefitName": "Separate air distribution ducts", "LowFloorH": 0.0, @@ -195,7 +195,7 @@ }, "EC_EnviromentalConditions_BatchFile": "DefaultClimatic.aenv", "EC_EnviromentalConditions_BatchEnabled": true, - "AC_CompressorType": "2-stage", + "AC_CompressorType": "2-Stage", "AC_CompressorTypeDerived": "Mechanical", "AC_CompressorCapacitykW": 18.0, "AC_COP": 3.5, @@ -207,10 +207,10 @@ "VEN_VentilationDuringCooling": "high", "AH_EngineWasteHeatkW": 0.0, "AH_FuelFiredHeaterkW": 30.0, - "AH_FuelEnergyToHeatToCoolant": 0.2, - "AH_CoolantHeatTransferredToAirCabinHeater": 0.75 + "AH_FuelEnergyToHeatToCoolant": 0.0, + "AH_CoolantHeatTransferredToAirCabinHeater": 0.0 }, - "Units": "fraction", + "Units": "Fraction", "Category": "Heating", "BenefitName": "Adjustable auxiliary heater", "LowFloorH": 0.02, @@ -280,7 +280,7 @@ }, "EC_EnviromentalConditions_BatchFile": "DefaultClimatic.aenv", "EC_EnviromentalConditions_BatchEnabled": true, - "AC_CompressorType": "2-stage", + "AC_CompressorType": "2-Stage", "AC_CompressorTypeDerived": "Mechanical", "AC_CompressorCapacitykW": 18.0, "AC_COP": 3.5, @@ -292,10 +292,10 @@ "VEN_VentilationDuringCooling": "high", "AH_EngineWasteHeatkW": 0.0, "AH_FuelFiredHeaterkW": 30.0, - "AH_FuelEnergyToHeatToCoolant": 0.2, - "AH_CoolantHeatTransferredToAirCabinHeater": 0.75 + "AH_FuelEnergyToHeatToCoolant": 0.0, + "AH_CoolantHeatTransferredToAirCabinHeater": 0.0 }, - "Units": "fraction", + "Units": "Fraction", "Category": "Heating", "BenefitName": "Adjustable coolant thermostat", "LowFloorH": 0.02, @@ -365,7 +365,7 @@ }, "EC_EnviromentalConditions_BatchFile": "DefaultClimatic.aenv", "EC_EnviromentalConditions_BatchEnabled": true, - "AC_CompressorType": "2-stage", + "AC_CompressorType": "2-Stage", "AC_CompressorTypeDerived": "Mechanical", "AC_CompressorCapacitykW": 18.0, "AC_COP": 3.5, @@ -377,14 +377,14 @@ "VEN_VentilationDuringCooling": "high", "AH_EngineWasteHeatkW": 0.0, "AH_FuelFiredHeaterkW": 30.0, - "AH_FuelEnergyToHeatToCoolant": 0.2, - "AH_CoolantHeatTransferredToAirCabinHeater": 0.75 + "AH_FuelEnergyToHeatToCoolant": 0.0, + "AH_CoolantHeatTransferredToAirCabinHeater": 0.0 }, "Units": "fraction", "Category": "Heating", "BenefitName": "Engine waste gas heat exchanger", "LowFloorH": 0.04, - "LowFloorV": 0.04, + "LowFloorV": 0.0, "LowFloorC": 0.0, "SemiLowFloorH": 0.0, "SemiLowFloorV": 0.0, @@ -393,7 +393,7 @@ "RaisedFloorV": 0.0, "RaisedFloorC": 0.0, "OnVehicle": false, - "ActiveVH": true, + "ActiveVH": false, "ActiveVV": false, "ActiveVC": false, "LineType": 0, @@ -450,7 +450,7 @@ }, "EC_EnviromentalConditions_BatchFile": "DefaultClimatic.aenv", "EC_EnviromentalConditions_BatchEnabled": true, - "AC_CompressorType": "2-stage", + "AC_CompressorType": "2-Stage", "AC_CompressorTypeDerived": "Mechanical", "AC_CompressorCapacitykW": 18.0, "AC_COP": 3.5, @@ -462,10 +462,10 @@ "VEN_VentilationDuringCooling": "high", "AH_EngineWasteHeatkW": 0.0, "AH_FuelFiredHeaterkW": 30.0, - "AH_FuelEnergyToHeatToCoolant": 0.2, - "AH_CoolantHeatTransferredToAirCabinHeater": 0.75 + "AH_FuelEnergyToHeatToCoolant": 0.0, + "AH_CoolantHeatTransferredToAirCabinHeater": 0.0 }, - "Units": "fraction", + "Units": "Fraction", "Category": "Heating", "BenefitName": "Heat pump systems", "LowFloorH": 0.06, @@ -535,7 +535,7 @@ }, "EC_EnviromentalConditions_BatchFile": "DefaultClimatic.aenv", "EC_EnviromentalConditions_BatchEnabled": true, - "AC_CompressorType": "2-stage", + "AC_CompressorType": "2-Stage", "AC_CompressorTypeDerived": "Mechanical", "AC_CompressorCapacitykW": 18.0, "AC_COP": 3.5, @@ -547,10 +547,10 @@ "VEN_VentilationDuringCooling": "high", "AH_EngineWasteHeatkW": 0.0, "AH_FuelFiredHeaterkW": 30.0, - "AH_FuelEnergyToHeatToCoolant": 0.2, - "AH_CoolantHeatTransferredToAirCabinHeater": 0.75 + "AH_FuelEnergyToHeatToCoolant": 0.0, + "AH_CoolantHeatTransferredToAirCabinHeater": 0.0 }, - "Units": "fraction", + "Units": "Fraction", "Category": "Insulation", "BenefitName": "Double-glazing", "LowFloorH": 0.04, @@ -620,7 +620,7 @@ }, "EC_EnviromentalConditions_BatchFile": "DefaultClimatic.aenv", "EC_EnviromentalConditions_BatchEnabled": true, - "AC_CompressorType": "2-stage", + "AC_CompressorType": "2-Stage", "AC_CompressorTypeDerived": "Mechanical", "AC_CompressorCapacitykW": 18.0, "AC_COP": 3.5, @@ -632,8 +632,8 @@ "VEN_VentilationDuringCooling": "high", "AH_EngineWasteHeatkW": 0.0, "AH_FuelFiredHeaterkW": 30.0, - "AH_FuelEnergyToHeatToCoolant": 0.2, - "AH_CoolantHeatTransferredToAirCabinHeater": 0.75 + "AH_FuelEnergyToHeatToCoolant": 0.0, + "AH_CoolantHeatTransferredToAirCabinHeater": 0.0 }, "Units": "fraction", "Category": "Insulation", @@ -705,7 +705,7 @@ }, "EC_EnviromentalConditions_BatchFile": "DefaultClimatic.aenv", "EC_EnviromentalConditions_BatchEnabled": true, - "AC_CompressorType": "2-stage", + "AC_CompressorType": "2-Stage", "AC_CompressorTypeDerived": "Mechanical", "AC_CompressorCapacitykW": 18.0, "AC_COP": 3.5, @@ -717,10 +717,10 @@ "VEN_VentilationDuringCooling": "high", "AH_EngineWasteHeatkW": 0.0, "AH_FuelFiredHeaterkW": 30.0, - "AH_FuelEnergyToHeatToCoolant": 0.2, - "AH_CoolantHeatTransferredToAirCabinHeater": 0.75 + "AH_FuelEnergyToHeatToCoolant": 0.0, + "AH_CoolantHeatTransferredToAirCabinHeater": 0.0 }, - "Units": "fraction", + "Units": "Fraction", "Category": "Ventilation", "BenefitName": "Fan control strategy (serial/parallel)", "LowFloorH": 0.02, diff --git a/Generic Vehicles/AAUXTestVehicles/24t Coach/testHVACssm_AllTechs.AHSM b/Generic Vehicles/AAUXTestVehicles/24t Coach/testHVACssm_AllTechs.AHSM index b97680cebe..ae53f10d55 100644 --- a/Generic Vehicles/AAUXTestVehicles/24t Coach/testHVACssm_AllTechs.AHSM +++ b/Generic Vehicles/AAUXTestVehicles/24t Coach/testHVACssm_AllTechs.AHSM @@ -45,7 +45,7 @@ }, "EC_EnviromentalConditions_BatchFile": "DefaultClimatic.aenv", "EC_EnviromentalConditions_BatchEnabled": true, - "AC_CompressorType": "2-stage", + "AC_CompressorType": "2-Stage", "AC_CompressorTypeDerived": "Mechanical", "AC_CompressorCapacitykW": 18.0, "AC_COP": 3.5, @@ -57,8 +57,8 @@ "VEN_VentilationDuringCooling": "high", "AH_EngineWasteHeatkW": 0.0, "AH_FuelFiredHeaterkW": 30.0, - "AH_FuelEnergyToHeatToCoolant": 0.2, - "AH_CoolantHeatTransferredToAirCabinHeater": 0.75 + "AH_FuelEnergyToHeatToCoolant": 0.0, + "AH_CoolantHeatTransferredToAirCabinHeater": 0.0 }, "TechList": { "$type": "VectoAuxiliaries.Hvac.SSMTechList, BusAuxiliaries", @@ -110,7 +110,7 @@ }, "EC_EnviromentalConditions_BatchFile": "DefaultClimatic.aenv", "EC_EnviromentalConditions_BatchEnabled": true, - "AC_CompressorType": "2-stage", + "AC_CompressorType": "2-Stage", "AC_CompressorTypeDerived": "Mechanical", "AC_CompressorCapacitykW": 18.0, "AC_COP": 3.5, @@ -122,10 +122,10 @@ "VEN_VentilationDuringCooling": "high", "AH_EngineWasteHeatkW": 0.0, "AH_FuelFiredHeaterkW": 30.0, - "AH_FuelEnergyToHeatToCoolant": 0.2, - "AH_CoolantHeatTransferredToAirCabinHeater": 0.75 + "AH_FuelEnergyToHeatToCoolant": 0.0, + "AH_CoolantHeatTransferredToAirCabinHeater": 0.0 }, - "Units": "fraction", + "Units": "Fraction", "Category": "Cooling", "BenefitName": "Separate air distribution ducts", "LowFloorH": 0.0, @@ -195,7 +195,7 @@ }, "EC_EnviromentalConditions_BatchFile": "DefaultClimatic.aenv", "EC_EnviromentalConditions_BatchEnabled": true, - "AC_CompressorType": "2-stage", + "AC_CompressorType": "2-Stage", "AC_CompressorTypeDerived": "Mechanical", "AC_CompressorCapacitykW": 18.0, "AC_COP": 3.5, @@ -207,10 +207,10 @@ "VEN_VentilationDuringCooling": "high", "AH_EngineWasteHeatkW": 0.0, "AH_FuelFiredHeaterkW": 30.0, - "AH_FuelEnergyToHeatToCoolant": 0.2, - "AH_CoolantHeatTransferredToAirCabinHeater": 0.75 + "AH_FuelEnergyToHeatToCoolant": 0.0, + "AH_CoolantHeatTransferredToAirCabinHeater": 0.0 }, - "Units": "fraction", + "Units": "Fraction", "Category": "Heating", "BenefitName": "Adjustable auxiliary heater", "LowFloorH": 0.02, @@ -280,7 +280,7 @@ }, "EC_EnviromentalConditions_BatchFile": "DefaultClimatic.aenv", "EC_EnviromentalConditions_BatchEnabled": true, - "AC_CompressorType": "2-stage", + "AC_CompressorType": "2-Stage", "AC_CompressorTypeDerived": "Mechanical", "AC_CompressorCapacitykW": 18.0, "AC_COP": 3.5, @@ -292,10 +292,10 @@ "VEN_VentilationDuringCooling": "high", "AH_EngineWasteHeatkW": 0.0, "AH_FuelFiredHeaterkW": 30.0, - "AH_FuelEnergyToHeatToCoolant": 0.2, - "AH_CoolantHeatTransferredToAirCabinHeater": 0.75 + "AH_FuelEnergyToHeatToCoolant": 0.0, + "AH_CoolantHeatTransferredToAirCabinHeater": 0.0 }, - "Units": "fraction", + "Units": "Fraction", "Category": "Heating", "BenefitName": "Adjustable coolant thermostat", "LowFloorH": 0.02, @@ -365,7 +365,7 @@ }, "EC_EnviromentalConditions_BatchFile": "DefaultClimatic.aenv", "EC_EnviromentalConditions_BatchEnabled": true, - "AC_CompressorType": "2-stage", + "AC_CompressorType": "2-Stage", "AC_CompressorTypeDerived": "Mechanical", "AC_CompressorCapacitykW": 18.0, "AC_COP": 3.5, @@ -377,14 +377,14 @@ "VEN_VentilationDuringCooling": "high", "AH_EngineWasteHeatkW": 0.0, "AH_FuelFiredHeaterkW": 30.0, - "AH_FuelEnergyToHeatToCoolant": 0.2, - "AH_CoolantHeatTransferredToAirCabinHeater": 0.75 + "AH_FuelEnergyToHeatToCoolant": 0.0, + "AH_CoolantHeatTransferredToAirCabinHeater": 0.0 }, "Units": "fraction", "Category": "Heating", "BenefitName": "Engine waste gas heat exchanger", "LowFloorH": 0.04, - "LowFloorV": 0.04, + "LowFloorV": 0.0, "LowFloorC": 0.0, "SemiLowFloorH": 0.0, "SemiLowFloorV": 0.0, @@ -393,7 +393,7 @@ "RaisedFloorV": 0.0, "RaisedFloorC": 0.0, "OnVehicle": true, - "ActiveVH": true, + "ActiveVH": false, "ActiveVV": false, "ActiveVC": false, "LineType": 0, @@ -450,7 +450,7 @@ }, "EC_EnviromentalConditions_BatchFile": "DefaultClimatic.aenv", "EC_EnviromentalConditions_BatchEnabled": true, - "AC_CompressorType": "2-stage", + "AC_CompressorType": "2-Stage", "AC_CompressorTypeDerived": "Mechanical", "AC_CompressorCapacitykW": 18.0, "AC_COP": 3.5, @@ -462,10 +462,10 @@ "VEN_VentilationDuringCooling": "high", "AH_EngineWasteHeatkW": 0.0, "AH_FuelFiredHeaterkW": 30.0, - "AH_FuelEnergyToHeatToCoolant": 0.2, - "AH_CoolantHeatTransferredToAirCabinHeater": 0.75 + "AH_FuelEnergyToHeatToCoolant": 0.0, + "AH_CoolantHeatTransferredToAirCabinHeater": 0.0 }, - "Units": "fraction", + "Units": "Fraction", "Category": "Heating", "BenefitName": "Heat pump systems", "LowFloorH": 0.06, @@ -535,7 +535,7 @@ }, "EC_EnviromentalConditions_BatchFile": "DefaultClimatic.aenv", "EC_EnviromentalConditions_BatchEnabled": true, - "AC_CompressorType": "2-stage", + "AC_CompressorType": "2-Stage", "AC_CompressorTypeDerived": "Mechanical", "AC_CompressorCapacitykW": 18.0, "AC_COP": 3.5, @@ -547,10 +547,10 @@ "VEN_VentilationDuringCooling": "high", "AH_EngineWasteHeatkW": 0.0, "AH_FuelFiredHeaterkW": 30.0, - "AH_FuelEnergyToHeatToCoolant": 0.2, - "AH_CoolantHeatTransferredToAirCabinHeater": 0.75 + "AH_FuelEnergyToHeatToCoolant": 0.0, + "AH_CoolantHeatTransferredToAirCabinHeater": 0.0 }, - "Units": "fraction", + "Units": "Fraction", "Category": "Insulation", "BenefitName": "Double-glazing", "LowFloorH": 0.04, @@ -620,7 +620,7 @@ }, "EC_EnviromentalConditions_BatchFile": "DefaultClimatic.aenv", "EC_EnviromentalConditions_BatchEnabled": true, - "AC_CompressorType": "2-stage", + "AC_CompressorType": "2-Stage", "AC_CompressorTypeDerived": "Mechanical", "AC_CompressorCapacitykW": 18.0, "AC_COP": 3.5, @@ -632,8 +632,8 @@ "VEN_VentilationDuringCooling": "high", "AH_EngineWasteHeatkW": 0.0, "AH_FuelFiredHeaterkW": 30.0, - "AH_FuelEnergyToHeatToCoolant": 0.2, - "AH_CoolantHeatTransferredToAirCabinHeater": 0.75 + "AH_FuelEnergyToHeatToCoolant": 0.0, + "AH_CoolantHeatTransferredToAirCabinHeater": 0.0 }, "Units": "fraction", "Category": "Insulation", @@ -705,7 +705,7 @@ }, "EC_EnviromentalConditions_BatchFile": "DefaultClimatic.aenv", "EC_EnviromentalConditions_BatchEnabled": true, - "AC_CompressorType": "2-stage", + "AC_CompressorType": "2-Stage", "AC_CompressorTypeDerived": "Mechanical", "AC_CompressorCapacitykW": 18.0, "AC_COP": 3.5, @@ -717,10 +717,10 @@ "VEN_VentilationDuringCooling": "high", "AH_EngineWasteHeatkW": 0.0, "AH_FuelFiredHeaterkW": 30.0, - "AH_FuelEnergyToHeatToCoolant": 0.2, - "AH_CoolantHeatTransferredToAirCabinHeater": 0.75 + "AH_FuelEnergyToHeatToCoolant": 0.0, + "AH_CoolantHeatTransferredToAirCabinHeater": 0.0 }, - "Units": "fraction", + "Units": "Fraction", "Category": "Ventilation", "BenefitName": "Fan control strategy (serial/parallel)", "LowFloorH": 0.02, @@ -746,7 +746,7 @@ ], "CValueVariation": 0.099999994039535522, "CValueVariationKW": 0.0, - "HValueVariation": 0.14000000059604645, + "HValueVariation": 0.0, "HValueVariationKW": 0.0, "VCValueVariation": 0.099999994039535522, "VCValueVariationKW": 0.0, @@ -762,7 +762,7 @@ "FuelLPerHBase": 0.151278213, "ElectricalWAdjusted": 617.1892, "MechanicalWBaseAdjusted": 349.774, - "FuelLPerHBaseAdjusted": 0.130099282, + "FuelLPerHBaseAdjusted": 0.151278213, "BaseHeatingW_Mechanical": 0.0, "BaseHeatingW_ElectricalCoolingHeating": 0.0, "BaseHeatingW_ElectricalVentilation": 0.0, @@ -778,7 +778,7 @@ "TechListAdjustedHeatingW_Mechanical": 0.0, "TechListAdjustedHeatingW_ElectricalCoolingHeating": 0.0, "TechListAdjustedHeatingW_ElectricalVentilation": 0.14000000059604645, - "TechListAdjustedHeatingW_FuelFiredHeating": 0.14000000059604645, + "TechListAdjustedHeatingW_FuelFiredHeating": 0.0, "TechListAdjustedCoolingW_Mechanical": 0.0, "TechListAdjustedCoolingW_ElectricalCoolingHeating": 0.099999994039535522, "TechListAdjustedCoolingW_ElectricalVentilation": 0.099999994039535522, @@ -799,5 +799,5 @@ "FuelPerHBase": 0.151278213, "ElectricalWAdjusted": 617.1892, "MechanicalWBaseAdjusted": 349.774, - "FuelPerHBaseAdjusted": 0.130099282 + "FuelPerHBaseAdjusted": 0.151278213 } \ No newline at end of file -- GitLab