From 186c309e54c57ee1a9e12b1064cfccc39fefd3ef Mon Sep 17 00:00:00 2001
From: =?UTF-8?q?=E2=80=9CGlenn?= <glenn@ascentsoftware.eu>
Date: Tue, 22 Mar 2016 08:12:33 +0100
Subject: [PATCH] Update AAUXTestVehicles files

---
 .../24t Coach/24t Coach_AAux_Zero.vecto       |  2 +-
 .../24t Coach/AdvAuxTest.aaux                 |  9 +--
 .../24t Coach/AdvAuxTest_Zero.aaux            |  3 +-
 .../AAUXTestVehicles/24t Coach/Zero.acmp      | 52 ++++++-------
 .../24t Coach/testHVACssm.AHSM                | 70 ++++++++---------
 .../24t Coach/testHVACssm_AllTechs.AHSM       | 78 +++++++++----------
 6 files changed, 107 insertions(+), 107 deletions(-)

diff --git a/Generic Vehicles/AAUXTestVehicles/24t Coach/24t Coach_AAux_Zero.vecto b/Generic Vehicles/AAUXTestVehicles/24t Coach/24t Coach_AAux_Zero.vecto
index 41f74c10c2..3f0945ad18 100644
--- a/Generic Vehicles/AAUXTestVehicles/24t Coach/24t Coach_AAux_Zero.vecto	
+++ b/Generic Vehicles/AAUXTestVehicles/24t Coach/24t Coach_AAux_Zero.vecto	
@@ -1,7 +1,7 @@
 {
   "Header": {
     "CreatedBy": "Nikolas.Hill@ricardo.com (59753f44-cf9b-4a64-b131-7b334ff25883)",
-    "Date": "19/01/2016 12:53:57",
+    "Date": "18/02/2016 15:10:02",
     "AppVersion": "2.0.4-AUX.Alpha.3",
     "FileVersion": 2
   },
diff --git a/Generic Vehicles/AAUXTestVehicles/24t Coach/AdvAuxTest.aaux b/Generic Vehicles/AAUXTestVehicles/24t Coach/AdvAuxTest.aaux
index 9149c5b2a0..092f8411f4 100644
--- a/Generic Vehicles/AAUXTestVehicles/24t Coach/AdvAuxTest.aaux	
+++ b/Generic Vehicles/AAUXTestVehicles/24t Coach/AdvAuxTest.aaux	
@@ -11,7 +11,7 @@
   "ElectricalUserInputsConfig": {
     "$type": "VectoAuxiliaries.Electrics.ElectricsUserInputsConfig, BusAuxiliaries",
     "PowerNetVoltage": 28.3,
-    "AlternatorMap": "",
+    "AlternatorMap": "Default_2Alt.AALT",
     "AlternatorGearEfficiency": 0.92,
     "ElectricalConsumers": {
       "$type": "VectoAuxiliaries.Electrics.ElectricalConsumerList, BusAuxiliaries",
@@ -264,7 +264,7 @@
     "AirSuspensionControl": "Mechanically",
     "Doors": "Pneumatic",
     "KneelingHeightMillimeters": 70.0,
-    "ActuationsMap": "testPneumaticActuationsMap.APAC",
+    "ActuationsMap": "testPneumaticActuationsMap.apac",
     "RetarderBrake": true,
     "SmartAirCompression": false,
     "SmartRegeneration": false
@@ -286,7 +286,7 @@
   },
   "HvacUserInputsConfig": {
     "$type": "VectoAuxiliaries.Hvac.HVACUserInputsConfig, BusAuxiliaries",
-    "SSMFilePath": "",
+    "SSMFilePath": "testHVACssm.AHSM",
     "BusDatabasePath": "BusDatabase.abdb",
     "SSMDisabled": false
   },
@@ -311,7 +311,6 @@
     "EngineIdleSpeed": 0.0,
     "PneumaticOverrunUtilisation": 0.0,
     "StoredEnergyEfficiency": 0.0,
-    "RunningCalc": false,
-    "Internal_Engine_Power": 0.0
+    "RunningCalc": false
   }
 }
\ No newline at end of file
diff --git a/Generic Vehicles/AAUXTestVehicles/24t Coach/AdvAuxTest_Zero.aaux b/Generic Vehicles/AAUXTestVehicles/24t Coach/AdvAuxTest_Zero.aaux
index cf2e413006..42014bbde6 100644
--- a/Generic Vehicles/AAUXTestVehicles/24t Coach/AdvAuxTest_Zero.aaux	
+++ b/Generic Vehicles/AAUXTestVehicles/24t Coach/AdvAuxTest_Zero.aaux	
@@ -286,7 +286,7 @@
     "AdBlueDosing": "Electric",
     "AirSuspensionControl": "Mechanically",
     "Doors": "Electric",
-    "KneelingHeightMillimeters": 1E-05,
+    "KneelingHeightMillimeters": 0.0,
     "ActuationsMap": "ZeroPneumaticActuationsMap.APAC",
     "RetarderBrake": true,
     "SmartAirCompression": false,
@@ -318,6 +318,7 @@
     "ClutchEngaged": false,
     "EngineDrivelinePower": 0.0,
     "EngineDrivelineTorque": 0.0,
+    "EngineInertia": 0.0,
     "EngineMotoringPower": 0.0,
     "EngineSpeed": 2000,
     "SmartElectrics": false,
diff --git a/Generic Vehicles/AAUXTestVehicles/24t Coach/Zero.acmp b/Generic Vehicles/AAUXTestVehicles/24t Coach/Zero.acmp
index c5c31bc2cf..f7c4eed8fb 100644
--- a/Generic Vehicles/AAUXTestVehicles/24t Coach/Zero.acmp	
+++ b/Generic Vehicles/AAUXTestVehicles/24t Coach/Zero.acmp	
@@ -1,27 +1,27 @@
 RPM,FlowRate [l/min],Power [on] [W],Power [off] [W]
-500,198,0.01,0.01
-600,239,0.01,0.01
-700,280,0.01,0.01
-800,322,0.01,0.01
-900,363,0.01,0.01
-1000,405,0.01,0.01
-1100,446,0.01,0.01
-1200,487,0.01,0.01
-1300,528,0.01,0.01
-1400,568,0.01,0.01
-1500,605,0.01,0.01
-1600,640,0.01,0.01
-1700,673,0.01,0.01
-1800,706,0.01,0.01
-1900,736,0.01,0.01
-2000,764,0.01,0.01
-2100,791,0.01,0.01
-2200,812,0.01,0.01
-2300,832,0.01,0.01
-2400,851,0.01,0.01
-2500,870,0.01,0.01
-2600,887,0.01,0.01
-2700,904,0.01,0.01
-2800,920,0.01,0.01
-2900,936,0.01,0.01
-3000,951,0.01,0.01
+500,198,0.0,0.00
+600,239,0.0,0.0
+700,280,0.0,0.0
+800,322,0.0,0.0
+900,363,0.0,0.0
+1000,405,0.0,0.0
+1100,446,0.0,0.0
+1200,487,0.0,0.0
+1300,528,0.0,0.0
+1400,568,0.0,0.0
+1500,605,0.0,0.0
+1600,640,0.0,0.0
+1700,673,0.0,0.0
+1800,706,0.0,0.0
+1900,736,0.0,0.0
+2000,764,0.0,0.0
+2100,791,0.0,0.0
+2200,812,0.0,0.0
+2300,832,0.0,0.0
+2400,851,0.0,0.0
+2500,870,0.0,0.0
+2600,887,0.0,0.0
+2700,904,0.0,0.0
+2800,920,0.0,0.0
+2900,936,0.0,0.0
+3000,951,0.0,0.0
diff --git a/Generic Vehicles/AAUXTestVehicles/24t Coach/testHVACssm.AHSM b/Generic Vehicles/AAUXTestVehicles/24t Coach/testHVACssm.AHSM
index 1b75fdccf6..5ff264ba04 100644
--- a/Generic Vehicles/AAUXTestVehicles/24t Coach/testHVACssm.AHSM	
+++ b/Generic Vehicles/AAUXTestVehicles/24t Coach/testHVACssm.AHSM	
@@ -45,7 +45,7 @@
     },
     "EC_EnviromentalConditions_BatchFile": "DefaultClimatic.aenv",
     "EC_EnviromentalConditions_BatchEnabled": true,
-    "AC_CompressorType": "2-stage",
+    "AC_CompressorType": "2-Stage",
     "AC_CompressorTypeDerived": "Mechanical",
     "AC_CompressorCapacitykW": 18.0,
     "AC_COP": 3.5,
@@ -57,8 +57,8 @@
     "VEN_VentilationDuringCooling": "high",
     "AH_EngineWasteHeatkW": 0.0,
     "AH_FuelFiredHeaterkW": 30.0,
-    "AH_FuelEnergyToHeatToCoolant": 0.2,
-    "AH_CoolantHeatTransferredToAirCabinHeater": 0.75
+    "AH_FuelEnergyToHeatToCoolant": 0.0,
+    "AH_CoolantHeatTransferredToAirCabinHeater": 0.0
   },
   "TechList": {
     "$type": "VectoAuxiliaries.Hvac.SSMTechList, BusAuxiliaries",
@@ -110,7 +110,7 @@
           },
           "EC_EnviromentalConditions_BatchFile": "DefaultClimatic.aenv",
           "EC_EnviromentalConditions_BatchEnabled": true,
-          "AC_CompressorType": "2-stage",
+          "AC_CompressorType": "2-Stage",
           "AC_CompressorTypeDerived": "Mechanical",
           "AC_CompressorCapacitykW": 18.0,
           "AC_COP": 3.5,
@@ -122,10 +122,10 @@
           "VEN_VentilationDuringCooling": "high",
           "AH_EngineWasteHeatkW": 0.0,
           "AH_FuelFiredHeaterkW": 30.0,
-          "AH_FuelEnergyToHeatToCoolant": 0.2,
-          "AH_CoolantHeatTransferredToAirCabinHeater": 0.75
+          "AH_FuelEnergyToHeatToCoolant": 0.0,
+          "AH_CoolantHeatTransferredToAirCabinHeater": 0.0
         },
-        "Units": "fraction",
+        "Units": "Fraction",
         "Category": "Cooling",
         "BenefitName": "Separate air distribution ducts",
         "LowFloorH": 0.0,
@@ -195,7 +195,7 @@
           },
           "EC_EnviromentalConditions_BatchFile": "DefaultClimatic.aenv",
           "EC_EnviromentalConditions_BatchEnabled": true,
-          "AC_CompressorType": "2-stage",
+          "AC_CompressorType": "2-Stage",
           "AC_CompressorTypeDerived": "Mechanical",
           "AC_CompressorCapacitykW": 18.0,
           "AC_COP": 3.5,
@@ -207,10 +207,10 @@
           "VEN_VentilationDuringCooling": "high",
           "AH_EngineWasteHeatkW": 0.0,
           "AH_FuelFiredHeaterkW": 30.0,
-          "AH_FuelEnergyToHeatToCoolant": 0.2,
-          "AH_CoolantHeatTransferredToAirCabinHeater": 0.75
+          "AH_FuelEnergyToHeatToCoolant": 0.0,
+          "AH_CoolantHeatTransferredToAirCabinHeater": 0.0
         },
-        "Units": "fraction",
+        "Units": "Fraction",
         "Category": "Heating",
         "BenefitName": "Adjustable auxiliary heater",
         "LowFloorH": 0.02,
@@ -280,7 +280,7 @@
           },
           "EC_EnviromentalConditions_BatchFile": "DefaultClimatic.aenv",
           "EC_EnviromentalConditions_BatchEnabled": true,
-          "AC_CompressorType": "2-stage",
+          "AC_CompressorType": "2-Stage",
           "AC_CompressorTypeDerived": "Mechanical",
           "AC_CompressorCapacitykW": 18.0,
           "AC_COP": 3.5,
@@ -292,10 +292,10 @@
           "VEN_VentilationDuringCooling": "high",
           "AH_EngineWasteHeatkW": 0.0,
           "AH_FuelFiredHeaterkW": 30.0,
-          "AH_FuelEnergyToHeatToCoolant": 0.2,
-          "AH_CoolantHeatTransferredToAirCabinHeater": 0.75
+          "AH_FuelEnergyToHeatToCoolant": 0.0,
+          "AH_CoolantHeatTransferredToAirCabinHeater": 0.0
         },
-        "Units": "fraction",
+        "Units": "Fraction",
         "Category": "Heating",
         "BenefitName": "Adjustable coolant thermostat",
         "LowFloorH": 0.02,
@@ -365,7 +365,7 @@
           },
           "EC_EnviromentalConditions_BatchFile": "DefaultClimatic.aenv",
           "EC_EnviromentalConditions_BatchEnabled": true,
-          "AC_CompressorType": "2-stage",
+          "AC_CompressorType": "2-Stage",
           "AC_CompressorTypeDerived": "Mechanical",
           "AC_CompressorCapacitykW": 18.0,
           "AC_COP": 3.5,
@@ -377,14 +377,14 @@
           "VEN_VentilationDuringCooling": "high",
           "AH_EngineWasteHeatkW": 0.0,
           "AH_FuelFiredHeaterkW": 30.0,
-          "AH_FuelEnergyToHeatToCoolant": 0.2,
-          "AH_CoolantHeatTransferredToAirCabinHeater": 0.75
+          "AH_FuelEnergyToHeatToCoolant": 0.0,
+          "AH_CoolantHeatTransferredToAirCabinHeater": 0.0
         },
         "Units": "fraction",
         "Category": "Heating",
         "BenefitName": "Engine waste gas heat exchanger",
         "LowFloorH": 0.04,
-        "LowFloorV": 0.04,
+        "LowFloorV": 0.0,
         "LowFloorC": 0.0,
         "SemiLowFloorH": 0.0,
         "SemiLowFloorV": 0.0,
@@ -393,7 +393,7 @@
         "RaisedFloorV": 0.0,
         "RaisedFloorC": 0.0,
         "OnVehicle": false,
-        "ActiveVH": true,
+        "ActiveVH": false,
         "ActiveVV": false,
         "ActiveVC": false,
         "LineType": 0,
@@ -450,7 +450,7 @@
           },
           "EC_EnviromentalConditions_BatchFile": "DefaultClimatic.aenv",
           "EC_EnviromentalConditions_BatchEnabled": true,
-          "AC_CompressorType": "2-stage",
+          "AC_CompressorType": "2-Stage",
           "AC_CompressorTypeDerived": "Mechanical",
           "AC_CompressorCapacitykW": 18.0,
           "AC_COP": 3.5,
@@ -462,10 +462,10 @@
           "VEN_VentilationDuringCooling": "high",
           "AH_EngineWasteHeatkW": 0.0,
           "AH_FuelFiredHeaterkW": 30.0,
-          "AH_FuelEnergyToHeatToCoolant": 0.2,
-          "AH_CoolantHeatTransferredToAirCabinHeater": 0.75
+          "AH_FuelEnergyToHeatToCoolant": 0.0,
+          "AH_CoolantHeatTransferredToAirCabinHeater": 0.0
         },
-        "Units": "fraction",
+        "Units": "Fraction",
         "Category": "Heating",
         "BenefitName": "Heat pump systems",
         "LowFloorH": 0.06,
@@ -535,7 +535,7 @@
           },
           "EC_EnviromentalConditions_BatchFile": "DefaultClimatic.aenv",
           "EC_EnviromentalConditions_BatchEnabled": true,
-          "AC_CompressorType": "2-stage",
+          "AC_CompressorType": "2-Stage",
           "AC_CompressorTypeDerived": "Mechanical",
           "AC_CompressorCapacitykW": 18.0,
           "AC_COP": 3.5,
@@ -547,10 +547,10 @@
           "VEN_VentilationDuringCooling": "high",
           "AH_EngineWasteHeatkW": 0.0,
           "AH_FuelFiredHeaterkW": 30.0,
-          "AH_FuelEnergyToHeatToCoolant": 0.2,
-          "AH_CoolantHeatTransferredToAirCabinHeater": 0.75
+          "AH_FuelEnergyToHeatToCoolant": 0.0,
+          "AH_CoolantHeatTransferredToAirCabinHeater": 0.0
         },
-        "Units": "fraction",
+        "Units": "Fraction",
         "Category": "Insulation",
         "BenefitName": "Double-glazing",
         "LowFloorH": 0.04,
@@ -620,7 +620,7 @@
           },
           "EC_EnviromentalConditions_BatchFile": "DefaultClimatic.aenv",
           "EC_EnviromentalConditions_BatchEnabled": true,
-          "AC_CompressorType": "2-stage",
+          "AC_CompressorType": "2-Stage",
           "AC_CompressorTypeDerived": "Mechanical",
           "AC_CompressorCapacitykW": 18.0,
           "AC_COP": 3.5,
@@ -632,8 +632,8 @@
           "VEN_VentilationDuringCooling": "high",
           "AH_EngineWasteHeatkW": 0.0,
           "AH_FuelFiredHeaterkW": 30.0,
-          "AH_FuelEnergyToHeatToCoolant": 0.2,
-          "AH_CoolantHeatTransferredToAirCabinHeater": 0.75
+          "AH_FuelEnergyToHeatToCoolant": 0.0,
+          "AH_CoolantHeatTransferredToAirCabinHeater": 0.0
         },
         "Units": "fraction",
         "Category": "Insulation",
@@ -705,7 +705,7 @@
           },
           "EC_EnviromentalConditions_BatchFile": "DefaultClimatic.aenv",
           "EC_EnviromentalConditions_BatchEnabled": true,
-          "AC_CompressorType": "2-stage",
+          "AC_CompressorType": "2-Stage",
           "AC_CompressorTypeDerived": "Mechanical",
           "AC_CompressorCapacitykW": 18.0,
           "AC_COP": 3.5,
@@ -717,10 +717,10 @@
           "VEN_VentilationDuringCooling": "high",
           "AH_EngineWasteHeatkW": 0.0,
           "AH_FuelFiredHeaterkW": 30.0,
-          "AH_FuelEnergyToHeatToCoolant": 0.2,
-          "AH_CoolantHeatTransferredToAirCabinHeater": 0.75
+          "AH_FuelEnergyToHeatToCoolant": 0.0,
+          "AH_CoolantHeatTransferredToAirCabinHeater": 0.0
         },
-        "Units": "fraction",
+        "Units": "Fraction",
         "Category": "Ventilation",
         "BenefitName": "Fan control strategy (serial/parallel)",
         "LowFloorH": 0.02,
diff --git a/Generic Vehicles/AAUXTestVehicles/24t Coach/testHVACssm_AllTechs.AHSM b/Generic Vehicles/AAUXTestVehicles/24t Coach/testHVACssm_AllTechs.AHSM
index b97680cebe..ae53f10d55 100644
--- a/Generic Vehicles/AAUXTestVehicles/24t Coach/testHVACssm_AllTechs.AHSM	
+++ b/Generic Vehicles/AAUXTestVehicles/24t Coach/testHVACssm_AllTechs.AHSM	
@@ -45,7 +45,7 @@
     },
     "EC_EnviromentalConditions_BatchFile": "DefaultClimatic.aenv",
     "EC_EnviromentalConditions_BatchEnabled": true,
-    "AC_CompressorType": "2-stage",
+    "AC_CompressorType": "2-Stage",
     "AC_CompressorTypeDerived": "Mechanical",
     "AC_CompressorCapacitykW": 18.0,
     "AC_COP": 3.5,
@@ -57,8 +57,8 @@
     "VEN_VentilationDuringCooling": "high",
     "AH_EngineWasteHeatkW": 0.0,
     "AH_FuelFiredHeaterkW": 30.0,
-    "AH_FuelEnergyToHeatToCoolant": 0.2,
-    "AH_CoolantHeatTransferredToAirCabinHeater": 0.75
+    "AH_FuelEnergyToHeatToCoolant": 0.0,
+    "AH_CoolantHeatTransferredToAirCabinHeater": 0.0
   },
   "TechList": {
     "$type": "VectoAuxiliaries.Hvac.SSMTechList, BusAuxiliaries",
@@ -110,7 +110,7 @@
           },
           "EC_EnviromentalConditions_BatchFile": "DefaultClimatic.aenv",
           "EC_EnviromentalConditions_BatchEnabled": true,
-          "AC_CompressorType": "2-stage",
+          "AC_CompressorType": "2-Stage",
           "AC_CompressorTypeDerived": "Mechanical",
           "AC_CompressorCapacitykW": 18.0,
           "AC_COP": 3.5,
@@ -122,10 +122,10 @@
           "VEN_VentilationDuringCooling": "high",
           "AH_EngineWasteHeatkW": 0.0,
           "AH_FuelFiredHeaterkW": 30.0,
-          "AH_FuelEnergyToHeatToCoolant": 0.2,
-          "AH_CoolantHeatTransferredToAirCabinHeater": 0.75
+          "AH_FuelEnergyToHeatToCoolant": 0.0,
+          "AH_CoolantHeatTransferredToAirCabinHeater": 0.0
         },
-        "Units": "fraction",
+        "Units": "Fraction",
         "Category": "Cooling",
         "BenefitName": "Separate air distribution ducts",
         "LowFloorH": 0.0,
@@ -195,7 +195,7 @@
           },
           "EC_EnviromentalConditions_BatchFile": "DefaultClimatic.aenv",
           "EC_EnviromentalConditions_BatchEnabled": true,
-          "AC_CompressorType": "2-stage",
+          "AC_CompressorType": "2-Stage",
           "AC_CompressorTypeDerived": "Mechanical",
           "AC_CompressorCapacitykW": 18.0,
           "AC_COP": 3.5,
@@ -207,10 +207,10 @@
           "VEN_VentilationDuringCooling": "high",
           "AH_EngineWasteHeatkW": 0.0,
           "AH_FuelFiredHeaterkW": 30.0,
-          "AH_FuelEnergyToHeatToCoolant": 0.2,
-          "AH_CoolantHeatTransferredToAirCabinHeater": 0.75
+          "AH_FuelEnergyToHeatToCoolant": 0.0,
+          "AH_CoolantHeatTransferredToAirCabinHeater": 0.0
         },
-        "Units": "fraction",
+        "Units": "Fraction",
         "Category": "Heating",
         "BenefitName": "Adjustable auxiliary heater",
         "LowFloorH": 0.02,
@@ -280,7 +280,7 @@
           },
           "EC_EnviromentalConditions_BatchFile": "DefaultClimatic.aenv",
           "EC_EnviromentalConditions_BatchEnabled": true,
-          "AC_CompressorType": "2-stage",
+          "AC_CompressorType": "2-Stage",
           "AC_CompressorTypeDerived": "Mechanical",
           "AC_CompressorCapacitykW": 18.0,
           "AC_COP": 3.5,
@@ -292,10 +292,10 @@
           "VEN_VentilationDuringCooling": "high",
           "AH_EngineWasteHeatkW": 0.0,
           "AH_FuelFiredHeaterkW": 30.0,
-          "AH_FuelEnergyToHeatToCoolant": 0.2,
-          "AH_CoolantHeatTransferredToAirCabinHeater": 0.75
+          "AH_FuelEnergyToHeatToCoolant": 0.0,
+          "AH_CoolantHeatTransferredToAirCabinHeater": 0.0
         },
-        "Units": "fraction",
+        "Units": "Fraction",
         "Category": "Heating",
         "BenefitName": "Adjustable coolant thermostat",
         "LowFloorH": 0.02,
@@ -365,7 +365,7 @@
           },
           "EC_EnviromentalConditions_BatchFile": "DefaultClimatic.aenv",
           "EC_EnviromentalConditions_BatchEnabled": true,
-          "AC_CompressorType": "2-stage",
+          "AC_CompressorType": "2-Stage",
           "AC_CompressorTypeDerived": "Mechanical",
           "AC_CompressorCapacitykW": 18.0,
           "AC_COP": 3.5,
@@ -377,14 +377,14 @@
           "VEN_VentilationDuringCooling": "high",
           "AH_EngineWasteHeatkW": 0.0,
           "AH_FuelFiredHeaterkW": 30.0,
-          "AH_FuelEnergyToHeatToCoolant": 0.2,
-          "AH_CoolantHeatTransferredToAirCabinHeater": 0.75
+          "AH_FuelEnergyToHeatToCoolant": 0.0,
+          "AH_CoolantHeatTransferredToAirCabinHeater": 0.0
         },
         "Units": "fraction",
         "Category": "Heating",
         "BenefitName": "Engine waste gas heat exchanger",
         "LowFloorH": 0.04,
-        "LowFloorV": 0.04,
+        "LowFloorV": 0.0,
         "LowFloorC": 0.0,
         "SemiLowFloorH": 0.0,
         "SemiLowFloorV": 0.0,
@@ -393,7 +393,7 @@
         "RaisedFloorV": 0.0,
         "RaisedFloorC": 0.0,
         "OnVehicle": true,
-        "ActiveVH": true,
+        "ActiveVH": false,
         "ActiveVV": false,
         "ActiveVC": false,
         "LineType": 0,
@@ -450,7 +450,7 @@
           },
           "EC_EnviromentalConditions_BatchFile": "DefaultClimatic.aenv",
           "EC_EnviromentalConditions_BatchEnabled": true,
-          "AC_CompressorType": "2-stage",
+          "AC_CompressorType": "2-Stage",
           "AC_CompressorTypeDerived": "Mechanical",
           "AC_CompressorCapacitykW": 18.0,
           "AC_COP": 3.5,
@@ -462,10 +462,10 @@
           "VEN_VentilationDuringCooling": "high",
           "AH_EngineWasteHeatkW": 0.0,
           "AH_FuelFiredHeaterkW": 30.0,
-          "AH_FuelEnergyToHeatToCoolant": 0.2,
-          "AH_CoolantHeatTransferredToAirCabinHeater": 0.75
+          "AH_FuelEnergyToHeatToCoolant": 0.0,
+          "AH_CoolantHeatTransferredToAirCabinHeater": 0.0
         },
-        "Units": "fraction",
+        "Units": "Fraction",
         "Category": "Heating",
         "BenefitName": "Heat pump systems",
         "LowFloorH": 0.06,
@@ -535,7 +535,7 @@
           },
           "EC_EnviromentalConditions_BatchFile": "DefaultClimatic.aenv",
           "EC_EnviromentalConditions_BatchEnabled": true,
-          "AC_CompressorType": "2-stage",
+          "AC_CompressorType": "2-Stage",
           "AC_CompressorTypeDerived": "Mechanical",
           "AC_CompressorCapacitykW": 18.0,
           "AC_COP": 3.5,
@@ -547,10 +547,10 @@
           "VEN_VentilationDuringCooling": "high",
           "AH_EngineWasteHeatkW": 0.0,
           "AH_FuelFiredHeaterkW": 30.0,
-          "AH_FuelEnergyToHeatToCoolant": 0.2,
-          "AH_CoolantHeatTransferredToAirCabinHeater": 0.75
+          "AH_FuelEnergyToHeatToCoolant": 0.0,
+          "AH_CoolantHeatTransferredToAirCabinHeater": 0.0
         },
-        "Units": "fraction",
+        "Units": "Fraction",
         "Category": "Insulation",
         "BenefitName": "Double-glazing",
         "LowFloorH": 0.04,
@@ -620,7 +620,7 @@
           },
           "EC_EnviromentalConditions_BatchFile": "DefaultClimatic.aenv",
           "EC_EnviromentalConditions_BatchEnabled": true,
-          "AC_CompressorType": "2-stage",
+          "AC_CompressorType": "2-Stage",
           "AC_CompressorTypeDerived": "Mechanical",
           "AC_CompressorCapacitykW": 18.0,
           "AC_COP": 3.5,
@@ -632,8 +632,8 @@
           "VEN_VentilationDuringCooling": "high",
           "AH_EngineWasteHeatkW": 0.0,
           "AH_FuelFiredHeaterkW": 30.0,
-          "AH_FuelEnergyToHeatToCoolant": 0.2,
-          "AH_CoolantHeatTransferredToAirCabinHeater": 0.75
+          "AH_FuelEnergyToHeatToCoolant": 0.0,
+          "AH_CoolantHeatTransferredToAirCabinHeater": 0.0
         },
         "Units": "fraction",
         "Category": "Insulation",
@@ -705,7 +705,7 @@
           },
           "EC_EnviromentalConditions_BatchFile": "DefaultClimatic.aenv",
           "EC_EnviromentalConditions_BatchEnabled": true,
-          "AC_CompressorType": "2-stage",
+          "AC_CompressorType": "2-Stage",
           "AC_CompressorTypeDerived": "Mechanical",
           "AC_CompressorCapacitykW": 18.0,
           "AC_COP": 3.5,
@@ -717,10 +717,10 @@
           "VEN_VentilationDuringCooling": "high",
           "AH_EngineWasteHeatkW": 0.0,
           "AH_FuelFiredHeaterkW": 30.0,
-          "AH_FuelEnergyToHeatToCoolant": 0.2,
-          "AH_CoolantHeatTransferredToAirCabinHeater": 0.75
+          "AH_FuelEnergyToHeatToCoolant": 0.0,
+          "AH_CoolantHeatTransferredToAirCabinHeater": 0.0
         },
-        "Units": "fraction",
+        "Units": "Fraction",
         "Category": "Ventilation",
         "BenefitName": "Fan control strategy (serial/parallel)",
         "LowFloorH": 0.02,
@@ -746,7 +746,7 @@
     ],
     "CValueVariation": 0.099999994039535522,
     "CValueVariationKW": 0.0,
-    "HValueVariation": 0.14000000059604645,
+    "HValueVariation": 0.0,
     "HValueVariationKW": 0.0,
     "VCValueVariation": 0.099999994039535522,
     "VCValueVariationKW": 0.0,
@@ -762,7 +762,7 @@
     "FuelLPerHBase": 0.151278213,
     "ElectricalWAdjusted": 617.1892,
     "MechanicalWBaseAdjusted": 349.774,
-    "FuelLPerHBaseAdjusted": 0.130099282,
+    "FuelLPerHBaseAdjusted": 0.151278213,
     "BaseHeatingW_Mechanical": 0.0,
     "BaseHeatingW_ElectricalCoolingHeating": 0.0,
     "BaseHeatingW_ElectricalVentilation": 0.0,
@@ -778,7 +778,7 @@
     "TechListAdjustedHeatingW_Mechanical": 0.0,
     "TechListAdjustedHeatingW_ElectricalCoolingHeating": 0.0,
     "TechListAdjustedHeatingW_ElectricalVentilation": 0.14000000059604645,
-    "TechListAdjustedHeatingW_FuelFiredHeating": 0.14000000059604645,
+    "TechListAdjustedHeatingW_FuelFiredHeating": 0.0,
     "TechListAdjustedCoolingW_Mechanical": 0.0,
     "TechListAdjustedCoolingW_ElectricalCoolingHeating": 0.099999994039535522,
     "TechListAdjustedCoolingW_ElectricalVentilation": 0.099999994039535522,
@@ -799,5 +799,5 @@
   "FuelPerHBase": 0.151278213,
   "ElectricalWAdjusted": 617.1892,
   "MechanicalWBaseAdjusted": 349.774,
-  "FuelPerHBaseAdjusted": 0.130099282
+  "FuelPerHBaseAdjusted": 0.151278213
 }
\ No newline at end of file
-- 