Stefanos Doumpoulakis authoredStefanos Doumpoulakis authored
VECTO Changelog
2022-09-01: Vecto 3.3.12.2800 Official Release
- Bugfixes (compared to VECTO 3.3.12.2769)
- [VECTO-1635] - Reading / Writing the ADAS Parameter ATEcoRollReleaseLockupClutch does not work
2022-08-01: Vecto 3.3.12.2769 Release Candidate
- Improvement
- [VECTO-1584] - Hashing library uses constructor that is deprecated in newer .net versions
- [VECTO-1619] - Adaptations of XML Results in transition period
- [VECTO-1619] - Reading Engine and Tyre component according to 2nd amendment (schema version 2.3)
- [VECTO-1461] - Alignment of Steering Pump Technology and Steered Axles not checked by VECTO
- [VECTO-1571] - Help file: Vehicle defined Torque Limitations
- [VECTO-1585] - Validate component hashes in declaration mode (disabled by default)
- [VECTO-1587] - update build script to include files required for xml parameter documentation
- [VECTO-1598] - Execution time in latest official release
- [VECTO-1608] - Adaptation of Reports (MRF/CIF) for transition in official VECTO Release
- Bugfixes:
- [VECTO-1622] - Unexpected response: Response Underload in LH LowLoad
- [VECTO-1623] - Unexpected response: Response Underload in LH EMS RefLoad
2022-04-29: Vecto 3.3.11.2675 Official Release
- Bugfixes (compared to VECTO 3.3.11.2645):
-
[VECTO-1557] - Simulation abort Generic Vehicle CityBus APT-S UD
-
[VECTO-1561] - Simulation abort with AT transmission
-
[VECTO-1567] - Different CO2 results with VECTO-3.3.11.2645 release candidate
-
[VECTO-1562] - Adapting WHTC Correction Factor weighting for LH Cycle
-
[VECTO-1560] - update toolchain for generating user manual
-
Added new VECTO parameter documentation
-
2022-03-30 Vecto 3.3.11.2645 Release Candidate
- Improvements:
- [VECTO-1474] - Implementation of ADAS in-the-loop simulation (Declaration and
Engineering mode)
- Engine stop/start
- Eco-roll
- Predictive cruise control: option 1,2; option 1,2,3
- Post-processing: fuel consumption correction for ICE-off phases
- Update shift strategy: EffShift for AMT and AT (Declaration and Engineering mode)
- [VECTO-1547] Update LongHaul driving cycle (Declaration mode)
- Dual-fuel support (Engineering mode)
- WHR support (Engineering mode)
- BusAuxiliaries model in engineering mode updated (simplified input)
- [VECTO-1473], [VECTO-1521] - Additional tyre dimensions
- [VECTO-1536] - Component XML 2nd Amendment (schema version 2.3)
- [VECTO-1536] - verify generated xml by default when using command-line hashing tool
- Bugfixes:
- [VECTO-1525] - PCC Preprocessing
- [VECTO-1529] - XML Schema 2.0: missing abstract XML type in Gears
- [VECTO-1550] - Error in hashing tool: sorting tires before comparing input data with MRF
- [VECTO-1551] - AT-P Transmission Bus Application: Error during braking phase
2020-12-01: Vecto 3.3.11.2526 Development Version
- Improvements:
-
Implementation of ADAS in-the-loop simulation (Declaration and Engineering mode)
- Engine stop/start
- Eco-roll
- Predictive cruise control: option 1,2; option 1,2,3
- Post-processing: fuel consumption correction for ICE-off phases
-
Update shift strategy: EffShift for AMT and AT (Declaration and Engineering mode)
-
Update LongHaul driving cycle (Declaration mode)
-
Dual-fuel support (Engineering mode)
-
WHR support (Engineering mode)
-
BusAuxiliaries model in engineering mode updated (simplified input)
-
Support to read driving cycle and EffShift parameters from file system (only once when application is started!)
-
EffShift Parameters
- The following EffShift parameters are read from the file “Declaration/EffShiftParameters.vtcu” if this file exists. (A sample file is provided in the VECTO archive)
- All parameters are optional, if a parameter is not provided the default value (see table below) is used
Parameter name | Value | Explanations |
---|---|---|
Rating_current_gear |
0.97 | Defines the minimum fuel efficiency advantage in a candidate gear to trigger a gear shift (i.e. 3% of a value of 0.97) - applies only for AMT transmissions |
Rating_current_gear_APT |
0.97 | Defines the minimum fuel efficiency advantage in a candidate gear to trigger a gear shift (i.e. 3% of a value of 0.97) - applies only for APT transmissions |
RatioEarly(Up/Down)shiftFC |
24 | In gears with a higher total drivetrain ratio (axle plus gearbox) than this parameter, “Efficiency shifts” are disabled, i.e. the shifts are only triggered by the shift lines. Rationale: Gear shift in this gears are primarily triggered by pow er demand. |
AllowedGearRangeFC |
2 | Defines the gear range for candidate gears for “Efficiency Shifts”(+/-) - applies only fot APT transmissions |
AllowedGearRangeFCAPT |
1 | Defines the gear range for candidate gears for “Efficiency Shifts”(+/-) - applies only fot APT transmissions with ≤ 6 gears Allowed |
GearRangeFCAPTSkipGear |
2 | Defines the gear range for candidate gears for “Efficiency Shifts”(+/-) - applies only fot APT transmissions with more than 6 gears |
AccelerationFactorNP98h |
0.5 | Defines the reduction of driver target acceleration in the engine speed range betw een nT98h and nP98h |
ATLookAheadTime |
0.8 | Defines look ahead time for rating of fuel consumption for AT transmissions. |
Declaration Missions
- The missions simulated in declaration mode folder “DeclarationMissions” if this folder exists.
- A folder with all declaration missions is provided in the VECTO archive
- LongHaul is the current candidate cycle #31
- Previous LongHaul cycle is provided as LongHaul_old
- Both LongHaul candidate cycles #13 and #31 are provided as well
- Cycles are only read once on application start
2020-07-29: Vecto 3.3.10.2401 Official Release
- Improvements:
- Handling of exempted vehicles (not changed since release candidate) - see next slides for details
- Bugfixes:
- No additional bugfixes compared to VECTO 3.3.10.2401
2020-07-01: Vecto 3.3.10.2373 Release Candidate
- Improvements:
- [VECTO-1421] - Added vehicle sub-group (CO2-standards to MRF and CIF)
- [VECTO 1449] - Handling of exempted vehicles: See next slide for details
- [VECTO-1404] - Corrected URL for CSS in MRF and CIF
- Bugfixes:
- [VECTO-1419] - Simulation abort in urban cycle: failed to find operating point on search braking power with TC gear
- [VECTO-1439] - Bugfix handling duplicate entries in engine full-load curve when intersecting with max-torque of gearbox
- [VECTO-1429] - error in XML schema 2.x for exempted vehicles - MaxNetPower1/2 are optional input parameters
Handling of exempted vehicles
- Axle configuration and sleeper cab are optional input parameters for exempted
vehicles (XML schema 1.0 and 2.2.1).
- OEMs are recommended to provide these parameters for exempted vehicles.
- If the axle configuration is provided as input parameter, the MRF contains the vehicle group.
- The sleeper cab input parameter is also part of the MRF if provided as input.
- Input parameters MaxNetPower1/2 are optional input parameters for all exempted vehicles.
- If provided in the input these parameters are part of the MRF for all exempted vehicle types
- It is recommended that those parameters are used to specify the rated power also for PEV (pure electric vehicles)
2020-12-15: Vecto 3.3.9.2175 Official Release
- Bugfixes (compared to version 3.3.9.2147)
- [VECTO-1374] - VECTO VTP error - regression update
2020-11-17: Vecto 3.3.9.2147 Release Candidate
- Bugfixes:
- [VECTO-1331] - VTP Mode does not function for vehicles of group 3
- [VECTO-1355] - VTP Simulation Abort
- [VECTO-1356] - PTO Losses not considered in VTP simulation
- [VECTO-1361] - Torque Converter in use for the First and Second Gear VTP file does not allow for this
- [VECTO-1372] - Deviation of CdxA Input vs. Output for HDV16
- [VECTO-1374] - VECTO VTP error
- Improvements:
- [VECTO-1360] - make unit tests execute in parallel
2020-08-14: Vecto 3.3.8.2052 Official Release
- Bugfixes:
- No additional bugfixes compared to VECTO 3.3.8.2024
2020-07-17: Vecto 3.3.8.2024 Release Candidate
- Bugfixes:
- [VECTO-1288] - Simulation Abort UD RL
- [VECTO-1327] - Simulation abort Construction RefLoad: unexpected response ResponseOverload
- [VECTO-1266] - Gear 4 Loss-Map was extrapolated
2020-05-18: Vecto 3.3.7.1964 Official Release
- Bugfixes:
- [VECTO-1254] - Hashing method does not ignore certain XML attributes
- [VECTO-1259] - Mission profile weighting factors for vehicles of group 16 are not correct
2020-03-31L Vecto 3.3.6.1916 Official Release
- Bugfixes:
- [VECTO-1250] - Error creating new gearbox file from scratch
2020-03-13: Vecto 3.3.6.1898 Release Candidate
- Improvement
- [VECTO-1239] - Adaptation of Mission Profile Weighting Factors
- [VECTO-1241] - Engineering mode: Adding support for additional PTO activations
- Bugfixes:
- [VECTO-1243] - Bug in VTP mode for heavy lorries
- [VECTO-1234] - urban cycle at reference load not running for bug when find braking operating point
2019-12-18: Vecto 3.3.5.1812 Official Release
- Bugfixes (compared to VECTO 3.3.5.1783-RC)
- [VECTO-1220] - Simulation Abort Urban Delivery RefLoad
2019-11-19: Vecto 3.3.5.1783 Release Candidate
- Improvement
- [VECTO-1194] - Handling input parameter 'vocational' for groups other than 4, 5, 9, 10
- [VECTO-1147] - Updating declaration mode cycles values in user manual
- [VECTO-1207] - run VECTO in 64bit mode by default
- Bugfixes:
- [VECTO-1074] - Vecto Calculation Aborts with Interpolation Error
- [VECTO-1159] - Simulation Abort in UrbanDelivery LowLoading
- [VECTO-1189] - Error in delaunay triangulation invariant violated
- [VECTO-1209] - Unexpected Response Response Overload
- [VECTO-1211] - Simulation Abort Urban Delivery Ref Load
- [VECTO-1214] - Validation of input data fails when gearbox speed limits are applied
2019-09-13: Vecto 3.3.4.1716 Official Release
- Bugfixes (compared to VECTO 3.3.4.1686-RC)
- [VECTO-1074] - Vecto Calculation Aborts with Interpolation Error ([VECTO-1046])
- [VECTO-1111] - Simulation Abort in Municipal Reference Load
2019-08-14: Vecto 3.3.4.1686 Release Candidate
- Improvement
- [VECTO-1042] - Add option to write results into a certain directory
- [VECTO-1064] - add weighting factors for vehicle groups 1, 2, 3, 11, 12, 16
- Bugfixes:
- [VECTO-1030] - Exceeded max iterations when searching for operating point! Failed to find operating point!
- [VECTO-1032] - Gear 5 LossMap data was extrapolated in Declaration Mode: range for loss map is not sufficient
- [VECTO-1067] - Vair and Beta correction for Aerodynamics
- [VECTO-1000] - Error Loss-Map extrapolation in Declaration Mode
- [VECTO-1040] - Gear 6 LossMap data was extrapolated in Declaration Mode
- [VECTO-1047] - Failed to find operating point on construction cycle, ref load, AT gearbox
2019-06-27: Vecto 3.3.3.1639 Official Release
- Bugfixes (compared to VECTO 3.3.3.1609-RC)
- [VECTO-1003] - Vecto Error: Loss-Map extrapolation in declaration mode required (issue VECTO-991)
- [VECTO-1006] - Failed to find torque converter operating point on UD cycle (issue VECTO-996)
- [VECTO-1010] - Unexpected Response: ResponseOverload in UD cycle (issue VECTO-996)
- [VECTO-1015] - XML Schema not correctly identified
- [VECTO-1019] - Error opening job in case a file is missing
- [VECTO-1020] - HashingTool Crashes
- [VECTO-1021] - Invalid hash of job data
2019-05-29: Vecto 3.3.3.1609 Release Candidate
- Improvement
- [VECTO-916] - Adding new tyre sizes
- [VECTO-946] - Refactoring XML reading
- [VECTO-965] - Add input fields for ADAS into VECTO GUI
- [VECTO-966] - Allow selecting Tank System for NG engines in GUI
- [VECTO-932] - Consistency in NA values in the vsum file
- Bugfixes:
- [VECTO-954] - Failed to find operating point for braking power (Fix for Notification Art. 10(2) - [VECTO-952])
- [VECTO-979] - VECTO Simulation abort with 8-speed MT transmission (Fix for Notification Art. 10(2) - [VECTO-978])
- [VECTO-931] - AT error in VECTO version 3.3.2.1519
- [VECTO-950] - Error when loading Engine Full-load curve
- [VECTO-967] - Engine-Only mode: Engine Torque reported in .vmod does not match the provided cycle
- [VECTO-980] - Error during simulation run
2019-03-29: Vecto 3.3.2.1548 Official Release
- Bugfixes (compared to 3.3.2.1519-RC)
- [VECTO-861] - 3.3.1: Torque converter not working correctly
- [VECTO-904] - Range for gear loss map not sufficient.
- [VECTO-909] - 3.3.2.1519: Problems running more than one input .xml
- [VECTO-917] - TargetVelocity (0.0000) and VehicleVelocity (>0) must be zero when vehicle is halting
- [VECTO-918] - RegionalDeliveryEMS LowLoading - ResponseSpeedLimitExceeded
- [VECTO-920] - Urban Delivery: Simulation Run Aborted, TargetVelocity and VehicleVelocity must be zero when vehicle is halting!