Code development platform for open source projects from the European Union institutions :large_blue_circle: EU Login authentication by SMS has been phased out. To see alternatives please check here

Skip to content
Snippets Groups Projects
Commit 076d9119 authored by Franz KOBER josef's avatar Franz KOBER josef
Browse files

changed aux components from Namespace 2.4 at vif

parent 5a53174e
No related branches found
No related tags found
No related merge requests found
......@@ -58,6 +58,111 @@
<xs:complexType name="Abstract_AUX_HEV-S_PrimaryBusDeclarationType" abstract="true"/>
<xs:complexType name="Abstract_AUX_IEPC_PrimaryBusDeclarationType" abstract="true"/>
<xs:complexType name="Abstract_AUX_PEV_PrimaryBusDeclarationType" abstract="true"/>
<xs:group name="BusAuxElectricSystemSupplySequenceGroup">
<xs:sequence>
<xs:element name="SmartAlternator" maxOccurs="unbounded">
<xs:complexType>
<xs:sequence>
<xs:element name="RatedCurrent">
<xs:annotation>
<xs:documentation>P295 - [A]</xs:documentation>
</xs:annotation>
<xs:simpleType>
<xs:restriction base="xs:integer">
<xs:minExclusive value="0"/>
</xs:restriction>
</xs:simpleType>
</xs:element>
<xs:element name="RatedVoltage">
<xs:annotation>
<xs:documentation>P296 - [V]</xs:documentation>
</xs:annotation>
<xs:simpleType>
<xs:restriction base="xs:integer">
<xs:enumeration value="12"/>
<xs:enumeration value="24"/>
<xs:enumeration value="48"/>
</xs:restriction>
</xs:simpleType>
</xs:element>
</xs:sequence>
</xs:complexType>
</xs:element>
<xs:element name="Battery" minOccurs="0" maxOccurs="unbounded">
<xs:complexType>
<xs:sequence>
<xs:element name="BatteryTechnology">
<xs:annotation>
<xs:documentation>P296 - enum</xs:documentation>
</xs:annotation>
<xs:simpleType>
<xs:restriction base="xs:string">
<xs:enumeration value="lead-acid battery – conventional"/>
<xs:enumeration value="lead-acid battery – AGM"/>
<xs:enumeration value="lead-acid battery – gel"/>
<xs:enumeration value="li-ion battery - high power"/>
<xs:enumeration value="li-ion battery - high energy"/>
</xs:restriction>
</xs:simpleType>
</xs:element>
<xs:element name="RatedCapacity" type="xs:integer">
<xs:annotation>
<xs:documentation>P299 - [Ah]</xs:documentation>
</xs:annotation>
</xs:element>
<xs:element name="NominalVoltage">
<xs:annotation>
<xs:documentation>P298 - [V]</xs:documentation>
</xs:annotation>
<xs:simpleType>
<xs:restriction base="xs:integer">
<xs:enumeration value="12"/>
<xs:enumeration value="24"/>
<xs:enumeration value="48"/>
</xs:restriction>
</xs:simpleType>
</xs:element>
</xs:sequence>
</xs:complexType>
</xs:element>
<xs:element name="Capacitor" minOccurs="0" maxOccurs="unbounded">
<xs:complexType>
<xs:sequence>
<xs:element name="CapacitorTechnology">
<xs:annotation>
<xs:documentation>P300 - [-]</xs:documentation>
</xs:annotation>
<xs:simpleType>
<xs:restriction base="xs:string">
<xs:enumeration value="with DCDC converter"/>
</xs:restriction>
</xs:simpleType>
</xs:element>
<xs:element name="RatedCapacitance">
<xs:annotation>
<xs:documentation>P301 - [F]</xs:documentation>
</xs:annotation>
<xs:simpleType>
<xs:restriction base="xs:integer">
<xs:minExclusive value="0"/>
</xs:restriction>
</xs:simpleType>
</xs:element>
<xs:element name="RatedVoltage">
<xs:annotation>
<xs:documentation>P302 - [V]</xs:documentation>
</xs:annotation>
<xs:simpleType>
<xs:restriction base="xs:integer">
<xs:minExclusive value="0"/>
</xs:restriction>
</xs:simpleType>
</xs:element>
</xs:sequence>
</xs:complexType>
</xs:element>
</xs:sequence>
</xs:group>
<xs:complexType name="AbstractADCDataDeclarationType" abstract="true">
<xs:complexContent>
<xs:extension base="v1.0:AbstractAngledriveDataDeclarationType"/>
......@@ -267,7 +372,7 @@
<xs:documentation>P294 - enum</xs:documentation>
</xs:annotation>
</xs:element>
<xs:group ref="v2.4:BusAuxElectricSystemSupplySequenceGroup" minOccurs="0"/>
<xs:group ref="vif:BusAuxElectricSystemSupplySequenceGroup" minOccurs="0"/>
<xs:element name="SupplyFromHEVPossible" type="xs:boolean">
<xs:annotation>
<xs:documentation>P303 - bool</xs:documentation>
......@@ -279,8 +384,8 @@
<xs:element name="PneumaticSystem">
<xs:complexType>
<xs:sequence>
<xs:group ref="v2.4:BusAuxPneumaticSystemGen_HEV-Px_SequenceGroup"/>
<xs:group ref="v2.4:BusAuxPneumaticSystemConsumerSequenceGroup"/>
<xs:group ref="vif:BusAuxPneumaticSystemGen_HEV-Px_SequenceGroup"/>
<xs:group ref="vif:BusAuxPneumaticSystemConsumerSequenceGroup"/>
</xs:sequence>
</xs:complexType>
</xs:element>
......@@ -420,8 +525,8 @@
<xs:element name="PneumaticSystem">
<xs:complexType>
<xs:sequence>
<xs:group ref="v2.4:BusAuxPneumaticSystemGen_IEPC_SequenceGroup"/>
<xs:group ref="v2.4:BusAuxPneumaticSystemConsumerSequenceGroup"/>
<xs:group ref="vif:BusAuxPneumaticSystemGen_IEPC_SequenceGroup"/>
<xs:group ref="vif:BusAuxPneumaticSystemConsumerSequenceGroup"/>
</xs:sequence>
</xs:complexType>
</xs:element>
......@@ -472,8 +577,8 @@
<xs:element name="PneumaticSystem">
<xs:complexType>
<xs:sequence>
<xs:group ref="v2.4:BusAuxPneumaticSystemGen_PEV_SequenceGroup"/>
<xs:group ref="v2.4:BusAuxPneumaticSystemConsumerSequenceGroup"/>
<xs:group ref="vif:BusAuxPneumaticSystemGen_PEV_SequenceGroup"/>
<xs:group ref="vif:BusAuxPneumaticSystemConsumerSequenceGroup"/>
</xs:sequence>
</xs:complexType>
</xs:element>
......@@ -1008,6 +1113,74 @@
</xs:element>
</xs:sequence>
</xs:group>
<xs:group name="BusAuxPneumaticSystemGen_HEV-Px_SequenceGroup">
<xs:sequence>
<xs:element name="SizeOfAirSupply" type="v2.4:PneumaticSystemTechnologyType">
<xs:annotation>
<xs:documentation>P309 - enum</xs:documentation>
</xs:annotation>
</xs:element>
<xs:element name="CompressorDrive">
<xs:annotation>
<xs:documentation>P310 - enum</xs:documentation>
</xs:annotation>
<xs:simpleType>
<xs:restriction base="xs:string">
<xs:enumeration value="mechanically"/>
<xs:enumeration value="electrically"/>
</xs:restriction>
</xs:simpleType>
</xs:element>
<xs:element name="Clutch" type="v2.4:PneumaticSystemClutchTypeType">
<xs:annotation>
<xs:documentation>P311 - enum</xs:documentation>
</xs:annotation>
</xs:element>
<xs:element name="CompressorRatio">
<xs:annotation>
<xs:documentation>P314 - [-]</xs:documentation>
</xs:annotation>
<xs:simpleType>
<xs:restriction base="v1.0:Double3">
<xs:minInclusive value="0.000"/>
</xs:restriction>
</xs:simpleType>
</xs:element>
<xs:element name="SmartCompressionSystem" type="xs:boolean">
<xs:annotation>
<xs:documentation>P313 - bool</xs:documentation>
</xs:annotation>
</xs:element>
</xs:sequence>
</xs:group>
<xs:group name="BusAuxPneumaticSystemGen_IEPC_SequenceGroup">
<xs:sequence>
<xs:element name="CompressorDrive">
<xs:annotation>
<xs:documentation>P310 - enum</xs:documentation>
</xs:annotation>
<xs:simpleType>
<xs:restriction base="xs:string">
<xs:enumeration value="electrically"/>
</xs:restriction>
</xs:simpleType>
</xs:element>
</xs:sequence>
</xs:group>
<xs:group name="BusAuxPneumaticSystemGen_PEV_SequenceGroup">
<xs:sequence>
<xs:element name="CompressorDrive">
<xs:annotation>
<xs:documentation>P310 - enum</xs:documentation>
</xs:annotation>
<xs:simpleType>
<xs:restriction base="xs:string">
<xs:enumeration value="electrically"/>
</xs:restriction>
</xs:simpleType>
</xs:element>
</xs:sequence>
</xs:group>
<xs:group name="BusAuxPneumaticSystemGen_HEV-S_SequenceGroup">
<xs:sequence>
<xs:element name="SizeOfAirSupply" type="v2.4:PneumaticSystemTechnologyType">
......
0% Loading or .
You are about to add 0 people to the discussion. Proceed with caution.
Please register or to comment