M6 and M7 Written, now looking at unit tests for them. WIP Checkpoint

parent 749e9539
No related branches found
No related tags found
No related merge requests found
Showing
with 652 additions and 75 deletions
......@@ -28,7 +28,7 @@
<UpdatePeriodically>false</UpdatePeriodically>
<UpdateRequired>false</UpdateRequired>
<MapFileExtensions>true</MapFileExtensions>
<ApplicationRevision>5</ApplicationRevision>
<ApplicationRevision>6</ApplicationRevision>
<ApplicationVersion>1.0.0.%2a</ApplicationVersion>
<UseApplicationTrust>false</UseApplicationTrust>
<PublishWizardCompleted>true</PublishWizardCompleted>
......@@ -168,6 +168,9 @@
<Content Include="testPneumaticActuationsMap_GOODMAP.csv">
<CopyToOutputDirectory>Always</CopyToOutputDirectory>
</Content>
<Content Include="testAlternatorMap - Copy.csv">
<CopyToOutputDirectory>Always</CopyToOutputDirectory>
</Content>
</ItemGroup>
<ItemGroup>
<ProjectReference Include="..\VECTOAux\VectoAuxiliaries\VectoAuxiliaries.vbproj">
......
......@@ -871,7 +871,7 @@ Private sub RefreshDisplays()
'M2
txtM2_out_AvgPowerAtAltFromElectrics.Text=auxEnvironment.M2.GetAveragePowerDemandAtAlternator
txtM2_out_AvgPowerAtCrankFromElectrics.Text=auxEnvironment.M2.GetAveragePowerAtCrank()
txtM2_out_AvgPowerAtCrankFromElectrics.Text=auxEnvironment.M2.GetAveragePowerAtCrankFromElectrics()
'M3
txtM3_out_AveragePowerAtCrankFromPneumatics.Text=auxEnvironment.M3.GetAveragePowerDemandAtCrankFromPneumatics
......
Amp,RPM,Efficiency
10,1500,0.615
27,1500,0.70
53,1500,0.1947
63,1500,0.00
68,1500,0.00
125,1500,0.00
136,1500,0.00
10,2000,0.62
27,2000,0.70
53,2000,0.30
63,2000,0.1462
68,2000,0.692
125,2000,0.00
136,2000,0.00
10,4000,0.64
27,4000,0.6721
53,4000,0.7211
63,4000,0.7400
68,4000,0.7352
125,4000,0.6800
136,4000,0.6694
10,6000,0.5300
27,6000,0.5798
53,6000,0.6560
63,6000,0.6853
68,6000,0.7000
125,6000,0.6329
136,6000,0.6200
10,7000,0.4750
27,7000,0.5337
53,7000,0.6235
63,7000,0.6580
68,7000,0.6824
125,7000,0.6094
136,7000,0.5953
Amp,RPM,Efficiency
10,1500,0.615
27,1500,0.70
53,1500,0.1947
63,1500,0.00
68,1500,0.00
125,1500,0.00
136,1500,0.00
10,2000,0.62
27,2000,0.70
53,2000,0.30
63,2000,0.1462
68,2000,0.692
125,2000,0.00
136,2000,0.00
10,4000,0.64
27,4000,0.6721
53,4000,0.7211
63,4000,0.7400
68,4000,0.7352
125,4000,0.6800
136,4000,0.6694
10,6000,0.5300
27,6000,0.5798
53,6000,0.6560
63,6000,0.6853
68,6000,0.7000
125,6000,0.6329
136,6000,0.6200
10,7000,0.4750
27,7000,0.5337
53,7000,0.6235
63,7000,0.6580
68,7000,0.6824
125,7000,0.6094
136,7000,0.5953
10,1500,0.5
27,1500,0.5
53,1500,0.5
63,1500,0.5
68,1500,0.5
125,1500,0.5
136,1500,0.5
10,2000,0.5
27,2000,0.5
53,2000,0.5
63,2000,0.5
68,2000,0.5
125,2000,0.5
136,2000,0.5
10,4000,0.5
27,4000,0.5
53,4000,0.5
63,4000,0.5
68,4000,0.5
125,4000,0.5
136,4000,0.5
10,6000,0.5
27,6000,0.5
53,6000,0.5
63,6000,0.5
68,6000,0.5
125,6000,0.5
136,6000,0.5
10,7000,0.5
27,7000,0.5
53,7000,0.5
63,7000,0.5
68,7000,0.5
125,7000,0.5
136,7000,0.5
......@@ -9,7 +9,6 @@
'
' See the LICENSE.txt for the specific language governing permissions and limitations.
Imports VectoAuxiliaries.ElectricalConsumers
Imports System.Collections.Generic
......

'Module 6: OVER-RUN smart and non-smart systems alternator and air compressor load calculations
Namespace DownstreamModules
Public Interface IM6
'Watts
Readonly Property OverrunFlag As Integer
Readonly Property SmartElecAndPneumaticsCompressorFlag As integer
ReadOnly Property SmartElecAndPneumaticAltPowerGenAtCrank As Single
ReadOnly Property SmartElecAndPneumaticAirCompPowerGenAtCrank As Single
ReadOnly Property SmartElecOnlyAltPowerGenAtCrank As Single
ReadOnly Property AveragePowerDemandAtCrankFromPneumatics As Single
ReadOnly Property SmartPneumaticOnlyAirCompPowerGenAtCrank As Single
ReadOnly Property AvgPowerDemandAtCrankFromElectricsIncHVAC As Single
ReadOnly Property SmartPneumaticsOnlyCompressorFlag As Integer
End Interface
End Namespace

Imports VectoAuxiliaries.Electrics
Imports VectoAuxiliaries.Pneumatics
Imports VectoAuxiliaries.Hvac
Namespace DownstreamModules
Public Interface IM7
ReadOnly Property SmartElectricalAndPneumaticAuxAltPowerGenAtCrank As Single
ReadOnly Property SmartElectricalAndPneumaticAuxAirCompPowerGenAtCrank As Single
ReadOnly property SmartElectricalOnlyAuxAltPowerGenAtCrank as single
ReadOnly Property SmartPneumaticOnlyAuxAirCompPowerGenAtCrank As Single
End Interface
End Namespace

Imports VectoAuxiliaries.Electrics
Imports VectoAuxiliaries.Pneumatics
Imports VectoAuxiliaries.Hvac
Namespace DownstreamModules
Public Class M6
Implements IM6
private _m1 As IM1_AverageHVACLoadDemand
private _m2 As IM2_AverageElectricalLoadDemand
private _m3 As IM3_AveragePneumaticLoadDemand
Private _m4 As IM4_AirCompressor
Private _m5 As IM5_SmartAlternatorSetGeneration
Private _signals As ISignals
Public ReadOnly Property AveragePowerDemandAtCrankFromPneumatics As Single Implements IM6.AveragePowerDemandAtCrankFromPneumatics
Get
Return _m3.GetAveragePowerDemandAtCrankFromPneumatics
End Get
End Property
Public ReadOnly Property AvgPowerDemandAtCrankFromElectricsIncHVAC As Single Implements IM6.AvgPowerDemandAtCrankFromElectricsIncHVAC
Get
Return Sum1
End Get
End Property
Public ReadOnly Property OverrunFlag As Integer Implements IM6.OverrunFlag
Get
Return VC0
End Get
End Property
Public ReadOnly Property SmartElecAndPneumaticAltPowerGenAtCrank As Single Implements IM6.SmartElecAndPneumaticAltPowerGenAtCrank
Get
Return Max1
End Get
End Property
Public ReadOnly Property SmartElecAndPneumaticAirCompPowerGenAtCrank As Single Implements IM6.SmartElecAndPneumaticAirCompPowerGenAtCrank
Get
Return Sum16
End Get
End Property
Public ReadOnly Property SmartElecAndPneumaticsCompressorFlag As integer Implements IM6.SmartElecAndPneumaticsCompressorFlag
Get
Return VC2
End Get
End Property
Public ReadOnly Property SmartElecOnlyAltPowerGenAtCrank As Single Implements IM6.SmartElecOnlyAltPowerGenAtCrank
Get
Return Max2
End Get
End Property
Public ReadOnly Property SmartPneumaticOnlyAirCompPowerGenAtCrank As Single Implements IM6.SmartPneumaticOnlyAirCompPowerGenAtCrank
Get
Return Sum19
End Get
End Property
Public ReadOnly Property SmartPneumaticsOnlyCompressorFlag As Integer Implements IM6.SmartPneumaticsOnlyCompressorFlag
Get
Return VC4
End Get
End Property
'switches
Private ReadOnly Property SW1 As Single
Get
Return If( _signals.SmartElectrics, _m5.AlternatorsGenerationPowerAtCrankTractionOnWatts,Sum1)
End Get
End Property
'Max's
'Max of Sum5 vs Sum10
Public ReadOnly Property Max1 As Single
Get
Return If( Sum5 > Sum10, Sum5, Sum10)
End Get
End Property
'Max of Sum10 vs Sum7
Public ReadOnly Property Max2 As Single
Get
Return If( Sum7 > Sum10, Sum7, Sum10)
End Get
End Property
'Value Choices
Public ReadOnly Property VC0 As Single
Get
Return If( Sum3<0,1,0)
End Get
End Property
Public ReadOnly Property VC1 As Single
Get
Return If( Sum12>0,1,0)
End Get
End Property
Public ReadOnly Property VC2 As Single
Get
Return If( Sum12<0 orelse Sum12=0,1,0)
End Get
End Property
Public ReadOnly Property VC3 As Single
Get
Return If( Sum13>0,1,0)
End Get
End Property
Public ReadOnly Property VC4 As Single
Get
Return If( Sum13<0 orelse Sum13=0, 1,0)
End Get
End Property
'Sums
Public ReadOnly Property Sum1 As Single
Get
Return _m1.AveragePowerDemandAtCrankFromHVACElectricsWatts + _m2.GetAveragePowerAtCrankFromElectrics
End Get
End Property
Public ReadOnly Property Sum2 As Single
Get
Return _signals.PreExistingAuxPower + _
_m1.AveragePowerDemandAtCrankFromHVACMechanicalsWatts + _
_m3.GetAveragePowerDemandAtCrankFromPneumatics + _
SW1
End Get
End Property
Public ReadOnly Property Sum3 As Single
Get
Return _signals.EngineMotoringPower + _
_signals.EngineDrivelinePower + _
Sum2
End Get
End Property
Public ReadOnly Property Sum4 As Single
Get
Return Sum3 - SW1 - _m3.GetAveragePowerDemandAtCrankFromPneumatics + _m4.GetPowerCompressorOff
End Get
End Property
Public ReadOnly Property Sum5 As Single
Get
Return OverrunFlag * Sum4
End Get
End Property
Public ReadOnly Property Sum6 As Single
Get
Return Sum4 - _m4.GetPowerCompressorOff + _m3.GetAveragePowerDemandAtCrankFromPneumatics
End Get
End Property
Public ReadOnly Property Sum7 As Single
Get
Return VC0 * Sum6
End Get
End Property
Public ReadOnly Property Sum8 As Single
Get
Return Sum4 + SW1
End Get
End Property
Public ReadOnly Property Sum9 As Single
Get
Return VC0 * Sum8
End Get
End Property
Public ReadOnly Property Sum10 As Single
Get
Return -1 * _m5.AlternatorsGenerationPowerAtCrankOverrunWatts
End Get
End Property
Public ReadOnly Property Sum11 As Single
Get
Return Sum5 - Max1
End Get
End Property
Public ReadOnly Property Sum12 As Single
Get
Return _m4.GetPowerDifference + Sum11
End Get
End Property
Public ReadOnly Property Sum13 As Single
Get
Return Sum9 + _m4.GetPowerDifference
End Get
End Property
Public ReadOnly Property Sum14 As Single
Get
Return VC1 * _m4.GetPowerCompressorOff
End Get
End Property
Public ReadOnly Property Sum15 As Single
Get
Return VC2 * _m4.GetPowerCompressorOn
End Get
End Property
Public ReadOnly property Sum16 as single
Get
Return Sum14 + Sum16
End Get
End Property
Public ReadOnly Property Sum17 As Single
Get
Return _m4.GetPowerCompressorOff * VC3
End Get
End Property
Public ReadOnly Property Sum18 As Single
Get
Return VC4 * _m4.GetPowerCompressorOn
End Get
End Property
Public ReadOnly Property Sum19 As Single
Get
Return Sum17 + Sum18
end get
End Property
Public Sub new ( m1 As IM1_AverageHVACLoadDemand,
m2 As IM2_AverageElectricalLoadDemand,
m3 As IM3_AveragePneumaticLoadDemand,
m4 As IM4_AirCompressor,
m5 As IM5_SmartAlternatorSetGeneration ,
signals As ISignals )
_m1=m1
_m2=m2
_m3=m3
_m4=m4
_m5=m5
_signals= signals
End Sub
End Class
End Namespace
Imports VectoAuxiliaries.Electrics
Imports VectoAuxiliaries.Pneumatics
Imports VectoAuxiliaries.Hvac
Namespace DownstreamModules
Public Class M7
implements IM7
Private _m5 As IM5_SmartAlternatorSetGeneration
Private _m6 As IM6
Private _signals As ISignals
'Boolan Conditions IE
Private readonly property C1 As Boolean
Get
Return _m6.OverrunFlag=1 Andalso _signals.ClutchEngaged Andalso _signals.InNeutral=false
End Get
End Property
'Internal Switched Outputs
Private readonly Property SW1 As Single
Get
Return If ( _signals.Idle, _m5.AlternatorsGenerationPowerAtCrankIdleWatts, _m5.AlternatorsGenerationPowerAtCrankTractionOnWatts)
End Get
End Property
Private readonly Property SW2 As Single
Get
Return If( C1, _m6.SmartElecAndPneumaticAltPowerGenAtCrank, SW1)
End Get
End Property
Private readonly Property SW3 As Single
Get
Return If( C1,_m6.SmartElecAndPneumaticAirCompPowerGenAtCrank,_m6.AveragePowerDemandAtCrankFromPneumatics)
End Get
End Property
Private readonly Property SW4 As Single
Get
Return If( C1,_m6.SmartElecOnlyAltPowerGenAtCrank,SW1)
End Get
End Property
Private readonly Property SW5 As Single
Get
Return If( C1, _m6.SmartPneumaticOnlyAirCompPowerGenAtCrank,_m6.AveragePowerDemandAtCrankFromPneumatics)
End Get
End Property
'Public readonly properties ( Outputs )
Public ReadOnly Property SmartElectricalAndPneumaticAuxAltPowerGenAtCrank As Single Implements IM7.SmartElectricalAndPneumaticAuxAltPowerGenAtCrank
Get
Return SW2
End Get
End Property
Public ReadOnly Property SmartElectricalAndPneumaticAuxAirCompPowerGenAtCrank As Single Implements IM7.SmartElectricalAndPneumaticAuxAirCompPowerGenAtCrank
Get
Return SW3
End Get
End Property
Public ReadOnly Property SmartElectricalOnlyAuxAltPowerGenAtCrank As Single Implements IM7.SmartElectricalOnlyAuxAltPowerGenAtCrank
Get
Return SW4
End Get
End Property
Public ReadOnly Property SmartPneumaticOnlyAuxAirCompPowerGenAtCrank As Single Implements IM7.SmartPneumaticOnlyAuxAirCompPowerGenAtCrank
Get
Return SW5
End Get
End Property
Public sub new ( m5 as IM5_SmartAlternatorSetGeneration, _
m6 As IM6, _
signals As ISignals)
_m5 = m5
_m6 = m6
_signals = signals
End Sub
End Class
End Namespace
......@@ -3,7 +3,7 @@
Public Interface IM2_AverageElectricalLoadDemand
Function GetAveragePowerDemandAtAlternator() As Single
Function GetAveragePowerAtCrank() As Single
Function GetAveragePowerAtCrankFromElectrics() As Single
End Interface
......
Public Interface IM5_SmartAlternatorSetGeneration

Namespace Electrics
Public Interface IM5_SmartAlternatorSetGeneration
......@@ -7,7 +11,10 @@ function AlternatorsGenerationPowerAtCrankTractionOnWatts() As Single
function AlternatorsGenerationPowerAtCrankOverrunWatts() As Single
End Interface
End Namespace
End Interface
......@@ -38,7 +38,7 @@
End Function
Public Function GetAveragePowerAtCrank() As Single Implements IM2_AverageElectricalLoadDemand.GetAveragePowerAtCrank
Public Function GetAveragePowerAtCrankFromElectrics() As Single Implements IM2_AverageElectricalLoadDemand.GetAveragePowerAtCrankFromElectrics
Dim ElectricalPowerDemandsWatts As Single = GetAveragePowerDemandAtAlternator()
Dim alternatorsEfficiency As Single = _module0.AlternatorsEfficiency
......
Public Interface IM1_AverageHVACLoadDemand

Namespace Pneumatics
Public Interface IM1_AverageHVACLoadDemand
Function AveragePowerDemandAtCrankFromHVACMechanicalsWatts() As Single
......@@ -14,3 +18,7 @@ Function HVACFuelingLitresPerHour() As Single
End Interface
End Namespace
Imports VectoAuxiliaries.Electrics
Imports VectoAuxiliaries.Pneumatics
Namespace Hvac
......@@ -7,49 +8,49 @@ Namespace Hvac
Private _m0 As IM0_NonSmart_AlternatorsSetEfficiency
Private _alternatorGearEfficiency As Single
Private _compressorGearEfficiency As single
Private _alternatorGearEfficiency As Single
Private _compressorGearEfficiency As Single
Private _hvacInputs As IHVACInputs
Private _hvacMap As IHVACMap
Private _signals As ISignals
Private _powernetVoltage As single
Private _powernetVoltage As Single
Private _steadyStateModel As IHVACSteadyStateModel
Public Sub new ( m0 As IM0_NonSmart_AlternatorsSetEfficiency, hvacMap As IHVACMap, hvacInputs As IHVACInputs, altGearEfficiency As Single,compressorGearEfficiency As Single, powernetVoltage As Single, signals As ISignals, ssm As IHVACSteadyStateModel )
Public Sub New(m0 As IM0_NonSmart_AlternatorsSetEfficiency, hvacMap As IHVACMap, hvacInputs As IHVACInputs, altGearEfficiency As Single, compressorGearEfficiency As Single, powernetVoltage As Single, signals As ISignals, ssm As IHVACSteadyStateModel)
'Sanity Check - Illegal operations without all params.
If m0 is Nothing then Throw New ArgumentException("Module0 as supplied is null")
If hvacMap is Nothing then Throw New ArgumentException("hvacMap as supplied is null")
If hvacInputs is Nothing then Throw New ArgumentException("hvacInputs as supplied is null")
If altGearEfficiency< ElectricConstants.AlternatorPulleyEfficiencyMin orelse altGearEfficiency> ElectricConstants.AlternatorPulleyEfficiencyMax then _
Throw New ArgumentException(String.Format("Gear efficiency must be between {0} and {1}",ElectricConstants.AlternatorPulleyEfficiencyMin,ElectricConstants.AlternatorPulleyEfficiencyMax ))
If m0 Is Nothing Then Throw New ArgumentException("Module0 as supplied is null")
If hvacMap Is Nothing Then Throw New ArgumentException("hvacMap as supplied is null")
If hvacInputs Is Nothing Then Throw New ArgumentException("hvacInputs as supplied is null")
If altGearEfficiency < ElectricConstants.AlternatorPulleyEfficiencyMin OrElse altGearEfficiency > ElectricConstants.AlternatorPulleyEfficiencyMax Then _
Throw New ArgumentException(String.Format("Gear efficiency must be between {0} and {1}", ElectricConstants.AlternatorPulleyEfficiencyMin, ElectricConstants.AlternatorPulleyEfficiencyMax))
If signals is Nothing then Throw New Exception ("Signals object as supplied is null")
If powernetVoltage< ElectricConstants.PowenetVoltageMin orelse powernetVoltage> ElectricConstants.PowenetVoltageMax then _
Throw New ArgumentException(String.Format("PowenetVoltage supplied must be in the range {0} to {1}",ElectricConstants.PowenetVoltageMin,ElectricConstants.PowenetVoltageMax))
If ssm is Nothing then Throw New ArgumentException("Steady State model was not supplied")
If compressorGearEfficiency< 0 orelse altGearEfficiency> 1 then _
Throw New ArgumentException(String.Format("Compressor Gear efficiency must be between {0} and {1}",0,1 ))
If signals Is Nothing Then Throw New Exception("Signals object as supplied is null")
If powernetVoltage < ElectricConstants.PowenetVoltageMin OrElse powernetVoltage > ElectricConstants.PowenetVoltageMax Then _
Throw New ArgumentException(String.Format("PowenetVoltage supplied must be in the range {0} to {1}", ElectricConstants.PowenetVoltageMin, ElectricConstants.PowenetVoltageMax))
If ssm Is Nothing Then Throw New ArgumentException("Steady State model was not supplied")
If compressorGearEfficiency < 0 OrElse altGearEfficiency > 1 Then _
Throw New ArgumentException(String.Format("Compressor Gear efficiency must be between {0} and {1}", 0, 1))
'Assign
_m0=m0
_hvacMap= hvacMap
_m0 = m0
_hvacMap = hvacMap
_hvacInputs = hvacInputs
_alternatorGearEfficiency=altGearEfficiency
_alternatorGearEfficiency = altGearEfficiency
_signals = signals
_steadyStateModel=ssm
_steadyStateModel = ssm
_compressorGearEfficiency = compressorGearEfficiency
_powernetVoltage=powernetVoltage
_powernetVoltage = powernetVoltage
End Sub
Public Function AveragePowerDemandAtCrankFromHVACMechanicalsWatts() As Single Implements IM1_AverageHVACLoadDemand.AveragePowerDemandAtCrankFromHVACMechanicalsWatts
Public Function AveragePowerDemandAtCrankFromHVACMechanicalsWatts() As Single Implements IM1_AverageHVACLoadDemand.AveragePowerDemandAtCrankFromHVACMechanicalsWatts
Return _steadyStateModel.HVACMechanicalLoadPowerWatts / _compressorGearEfficiency
......@@ -61,15 +62,15 @@ Namespace Hvac
End Function
Public Function AveragePowerDemandAtCrankFromHVACElectricsWatts() As Single Implements IM1_AverageHVACLoadDemand.AveragePowerDemandAtCrankFromHVACElectricsWatts
Public Function AveragePowerDemandAtCrankFromHVACElectricsWatts() As Single Implements IM1_AverageHVACLoadDemand.AveragePowerDemandAtCrankFromHVACElectricsWatts
Return _steadyStateModel.HVACElectricalLoadPowerWatts/ _m0.AlternatorsEfficiency()
Return _steadyStateModel.HVACElectricalLoadPowerWatts / _m0.AlternatorsEfficiency()
End Function
Public Function HVACFuelingLitresPerHour() As Single Implements IM1_AverageHVACLoadDemand.HVACFuelingLitresPerHour
Public Function HVACFuelingLitresPerHour() As Single Implements IM1_AverageHVACLoadDemand.HVACFuelingLitresPerHour
Return _steadyStateModel.HVACFuellingLitresPerHour
......
Public Interface ISignals
Property PreExistingAuxPower As single
Property EngineMotoringPower As single
property EngineDrivelinePower as single
property SmartElectrics As Boolean
......@@ -11,7 +9,7 @@ Property EngineSpeed as integer
Property SmartPneumatics As Boolean
Property TotalCycleTimeSeconds As Integer
property EngineDrivelineTorque as single
Property Idle As Boolean
Property InNeutral As Boolean
End Interface
......@@ -2,6 +2,8 @@
Public Class Signals
Implements ISignals
Public Property ClutchEngaged As Boolean Implements ISignals.ClutchEngaged
Public Property EngineDrivelinePower As Single Implements ISignals.EngineDrivelinePower
......@@ -18,6 +20,12 @@ Implements ISignals
Public Property TotalCycleTimeSeconds As Integer Implements ISignals.TotalCycleTimeSeconds
Public Property PreExistingAuxPower As Single Implements ISignals.PreExistingAuxPower
Public Property Idle As Boolean Implements ISignals.Idle
Public Property InNeutral As Boolean Implements ISignals.InNeutral
End Class
......
......@@ -73,6 +73,9 @@
</ItemGroup>
<ItemGroup>
<Compile Include="AuxillaryEnvironment.vb" />
<Compile Include="DownstreamModules\IM6.vb" />
<Compile Include="DownstreamModules\IM7.vb" />
<Compile Include="DownstreamModules\M7.vb" />
<Compile Include="Electrics\AlternatorMapValues.vb" />
<Compile Include="Electrics\AlternatorMap.vb" />
<Compile Include="Electrics\ElectricsUserInputsConfig.vb" />
......@@ -103,6 +106,7 @@
<Compile Include="Hvac\IM1_AverageHVACLoadDemand.vb" />
<Compile Include="ISignals.vb" />
<Compile Include="IVectoInputs.vb" />
<Compile Include="DownstreamModules\M6.vb" />
<Compile Include="Pneumatics\ActuationsKey.vb" />
<Compile Include="Pneumatics\IM3_AveragePneumaticLoadDemand.vb" />
<Compile Include="Pneumatics\M4_AirCompressor.vb" />
......

Imports VectoAuxiliaries.Electrics
Imports VectoAuxiliaries.Pneumatics
Imports VectoAuxiliaries.Hvac
Imports VectoAuxiliaries.DownstreamModules
Public Class M1_Mock
Implements IM1_AverageHVACLoadDemand
Public _AveragePowerDemandAtAlternatorFromHVACElectricsWatts As Single
public _AveragePowerDemandAtCrankFromHVACElectricsWatts As single
Public _AveragePowerDemandAtCrankFromHVACMechanicalsWatts As Single
Public _HVACFuelingLitresPerHour As single
Public Function AveragePowerDemandAtAlternatorFromHVACElectricsWatts() As Single Implements IM1_AverageHVACLoadDemand.AveragePowerDemandAtAlternatorFromHVACElectricsWatts
Return AveragePowerDemandAtAlternatorFromHVACElectricsWatts
End Function
Public Function AveragePowerDemandAtCrankFromHVACElectricsWatts() As Single Implements IM1_AverageHVACLoadDemand.AveragePowerDemandAtCrankFromHVACElectricsWatts
Return _AveragePowerDemandAtCrankFromHVACElectricsWatts
End Function
Public Function AveragePowerDemandAtCrankFromHVACMechanicalsWatts() As Single Implements IM1_AverageHVACLoadDemand.AveragePowerDemandAtCrankFromHVACMechanicalsWatts
Return _AveragePowerDemandAtCrankFromHVACMechanicalsWatts
End Function
Public Function HVACFuelingLitresPerHour() As Single Implements IM1_AverageHVACLoadDemand.HVACFuelingLitresPerHour
Return _HVACFuelingLitresPerHour
End Function
Public Sub new ( AveragePowerDemandAtAlternatorFromHVACElectricsWatts As Single, _
AveragePowerDemandAtCrankFromHVACElectricsWatts As single, _
AveragePowerDemandAtCrankFromHVACMechanicalsWatts As Single, _
HVACFuelingLitresPerHour As single)
'Assign Values
_AveragePowerDemandAtAlternatorFromHVACElectricsWatts = AveragePowerDemandAtAlternatorFromHVACElectricsWatts
_AveragePowerDemandAtCrankFromHVACElectricsWatts = AveragePowerDemandAtCrankFromHVACElectricsWatts
_AveragePowerDemandAtCrankFromHVACMechanicalsWatts = AveragePowerDemandAtCrankFromHVACMechanicalsWatts
_HVACFuelingLitresPerHour = HVACFuelingLitresPerHour
End Sub
End Class
Imports VectoAuxiliaries.Electrics
Imports VectoAuxiliaries.Pneumatics
Imports VectoAuxiliaries.Hvac
Imports VectoAuxiliaries.DownstreamModules
Public Class M2_Mock
Implements IM2_AverageElectricalLoadDemand
Public _GetAveragePowerAtCrankFromElectrics As Single
Public _GetAveragePowerDemandAtAlternator As Single
Public Function GetAveragePowerAtCrankFromElectrics() As Single Implements IM2_AverageElectricalLoadDemand.GetAveragePowerAtCrankFromElectrics
Return _GetAveragePowerAtCrankFromElectrics
End Function
Public Function GetAveragePowerDemandAtAlternator() As Single Implements IM2_AverageElectricalLoadDemand.GetAveragePowerDemandAtAlternator
Return _GetAveragePowerDemandAtAlternator
End Function
Public Sub new ( GetAveragePowerAtCrankFromElectrics As Single,GetAveragePowerDemandAtAlternator As single )
_GetAveragePowerAtCrankFromElectrics = GetAveragePowerAtCrankFromElectrics
_GetAveragePowerDemandAtAlternator = GetAveragePowerDemandAtAlternator
End Sub
End Class
Imports VectoAuxiliaries.Electrics
Imports VectoAuxiliaries.Pneumatics
Imports VectoAuxiliaries.Hvac
Imports VectoAuxiliaries.DownstreamModules
Public Class M3_Mock
Implements IM3_AveragePneumaticLoadDemand
public _GetAveragePowerDemandAtCrankFromPneumatics as single
public _TotalAirConsumedPerCycle as single
Public Function GetAveragePowerDemandAtCrankFromPneumatics() As Single Implements IM3_AveragePneumaticLoadDemand.GetAveragePowerDemandAtCrankFromPneumatics
Return _GetAveragePowerDemandAtCrankFromPneumatics
End Function
Public Function TotalAirConsumedPerCycle() As Single Implements IM3_AveragePneumaticLoadDemand.TotalAirConsumedPerCycle
Return _TotalAirConsumedPerCycle
End Function
Public Sub new ( GetAveragePowerDemandAtCrankFromPneumatics As Single,TotalAirConsumedPerCycle As single )
_GetAveragePowerDemandAtCrankFromPneumatics= GetAveragePowerDemandAtCrankFromPneumatics
_TotalAirConsumedPerCycle = TotalAirConsumedPerCycle
End Sub
End Class