stop start engine: apply whtc and ncv correction factors to ESS fuel consumption as well

WHR: apply ESS utility factor for WHR power as well.
parent 036d75f7
Branches
Tags
No related merge requests found
......@@ -132,7 +132,7 @@ namespace TUGraz.VectoCore.Models.SimulationComponent.Impl {
var result = fuel.ConsumptionMap.GetFuelConsumption(auxDemand, ModelData.IdleSpeed);
var fcESS = result.Value * (1 - EngineStopStartUtilityFactor);
var fcESS = result.Value * (1 - EngineStopStartUtilityFactor) * fuel.FuelData.HeatingValueCorrection * WHTCCorrectionFactor(fuel.FuelData);
var fcFinal = fcESS;
container[ModalResultField.FCMap, fuel.FuelData] = fc;
......@@ -144,6 +144,20 @@ namespace TUGraz.VectoCore.Models.SimulationComponent.Impl {
}
}
protected override void WriteWHRPower(IModalDataContainer container, PerSecond engineSpeed, NewtonMeter engineTorque)
{
var pWHRelMap = 0.SI<Watt>();
var pWHRelCorr = 0.SI<Watt>();
var pWHRmechMap = 0.SI<Watt>();
var pWHRmechCorr = 0.SI<Watt>();
GetWHRPower(ModelData.ElectricalWHR, engineSpeed, engineTorque, ref pWHRelMap, ref pWHRelCorr);
GetWHRPower(ModelData.MechanicalWHR, engineSpeed, engineTorque, ref pWHRmechMap, ref pWHRmechCorr);
container[ModalResultField.P_WHR_el_map] = (1 - EngineStopStartUtilityFactor) * pWHRelMap;
container[ModalResultField.P_WHR_el_corr] = (1 - EngineStopStartUtilityFactor) * pWHRelCorr;
container[ModalResultField.P_WHR_mech_map] = (1 - EngineStopStartUtilityFactor) * pWHRmechMap;
container[ModalResultField.P_WHR_mech_corr] = (1 - EngineStopStartUtilityFactor) * pWHRmechCorr;
}
}
}