adding several more testcases for SSM calculations, calculating cooling power

parent 18313f15
No related branches found
Tags Release/v3.3.8.2052
No related merge requests found
using System.Collections.Generic;
using System;
using System.Collections.Generic;
using System.Diagnostics;
using System.Linq;
using Moq;
using NUnit.Framework;
......@@ -21,31 +23,122 @@ public class SSMTestHeatingCooling
{
[
TestCase(BusHVACSystemConfiguration.Configuration1, HeatPumpType.none, HeatPumpType.none, 1, 0, 0.0),
TestCase(BusHVACSystemConfiguration.Configuration1, HeatPumpType.none, HeatPumpType.none, 6, 0, 0.0),
TestCase(BusHVACSystemConfiguration.Configuration1, HeatPumpType.none, HeatPumpType.none, 8, 0, 0.0),
TestCase(BusHVACSystemConfiguration.Configuration1, HeatPumpType.none, HeatPumpType.none, 11, 0, 0.0),
TestCase(BusHVACSystemConfiguration.Configuration2, HeatPumpType.non_R_744_2_stage, HeatPumpType.none, 1, 0, 0.0),
TestCase(BusHVACSystemConfiguration.Configuration2, HeatPumpType.non_R_744_2_stage, HeatPumpType.none, 6, 299.88, 0.0),
TestCase(BusHVACSystemConfiguration.Configuration2, HeatPumpType.non_R_744_2_stage, HeatPumpType.none, 8, 287.8848, 1.0156),
TestCase(BusHVACSystemConfiguration.Configuration2, HeatPumpType.non_R_744_2_stage, HeatPumpType.none, 11, 287.8848, 1351.1654),
TestCase(BusHVACSystemConfiguration.Configuration3, HeatPumpType.none, HeatPumpType.none, 1, 0, 0.0),
TestCase(BusHVACSystemConfiguration.Configuration3, HeatPumpType.none, HeatPumpType.none, 6, 0, 0.0),
TestCase(BusHVACSystemConfiguration.Configuration3, HeatPumpType.none, HeatPumpType.none, 8, 0, 0.0),
TestCase(BusHVACSystemConfiguration.Configuration3, HeatPumpType.none, HeatPumpType.none, 11, 0, 0.0),
TestCase(BusHVACSystemConfiguration.Configuration4, HeatPumpType.non_R_744_2_stage, HeatPumpType.none, 1, 0, 0.0),
TestCase(BusHVACSystemConfiguration.Configuration4, HeatPumpType.non_R_744_2_stage, HeatPumpType.none, 6, 856.80, 0.0),
TestCase(BusHVACSystemConfiguration.Configuration4, HeatPumpType.non_R_744_2_stage, HeatPumpType.none, 8, 822.5280, 633.1093),
TestCase(BusHVACSystemConfiguration.Configuration4, HeatPumpType.non_R_744_2_stage, HeatPumpType.none, 11, 822.5280, 2000.0),
TestCase(BusHVACSystemConfiguration.Configuration6, HeatPumpType.none, HeatPumpType.non_R_744_2_stage, 6, 856.80, 0.0)
// only mechanical heatpumps
TestCase(BusHVACSystemConfiguration.Configuration1 , 1 , HeatPumpType.none , HeatPumpType.none , 299.88 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration1 , 6 , HeatPumpType.none , HeatPumpType.none , 299.88 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration1 , 8 , HeatPumpType.none , HeatPumpType.none , 287.8848 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration1 , 11 , HeatPumpType.none , HeatPumpType.none , 287.8848 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration2 , 1 , HeatPumpType.non_R_744_2_stage , HeatPumpType.none , 299.88 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration2 , 6 , HeatPumpType.non_R_744_2_stage , HeatPumpType.none , 299.88 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration2 , 8 , HeatPumpType.non_R_744_2_stage , HeatPumpType.none , 287.8848 , 1.0156) ,
TestCase(BusHVACSystemConfiguration.Configuration2 , 11 , HeatPumpType.non_R_744_2_stage , HeatPumpType.none , 287.8848 , 1351.1654) ,
TestCase(BusHVACSystemConfiguration.Configuration3 , 1 , HeatPumpType.none , HeatPumpType.none , 428.400 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration3 , 6 , HeatPumpType.none , HeatPumpType.none , 856.800 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration3 , 8 , HeatPumpType.none , HeatPumpType.none , 822.5280 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration3 , 11 , HeatPumpType.none , HeatPumpType.none , 822.5280 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration4 , 1 , HeatPumpType.non_R_744_2_stage , HeatPumpType.none , 428.400 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration4 , 6 , HeatPumpType.non_R_744_2_stage , HeatPumpType.none , 856.80 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration4 , 8 , HeatPumpType.non_R_744_2_stage , HeatPumpType.none , 822.5280 , 633.1093) ,
TestCase(BusHVACSystemConfiguration.Configuration4 , 11 , HeatPumpType.non_R_744_2_stage , HeatPumpType.none , 822.5280 , 2000.0) ,
TestCase(BusHVACSystemConfiguration.Configuration5 , 1 , HeatPumpType.none , HeatPumpType.non_R_744_3_stage , 428.400 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration5 , 6 , HeatPumpType.none , HeatPumpType.non_R_744_3_stage , 856.80 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration5 , 8 , HeatPumpType.none , HeatPumpType.non_R_744_3_stage , 822.528 , 612.7957) ,
TestCase(BusHVACSystemConfiguration.Configuration5 , 11 , HeatPumpType.none , HeatPumpType.non_R_744_3_stage , 822.528 , 2965.1077) ,
TestCase(BusHVACSystemConfiguration.Configuration6 , 1 , HeatPumpType.none , HeatPumpType.non_R_744_3_stage , 428.400 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration6 , 6 , HeatPumpType.none , HeatPumpType.non_R_744_3_stage , 856.80 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration6 , 8 , HeatPumpType.none , HeatPumpType.non_R_744_3_stage , 822.528 , 612.7957) ,
TestCase(BusHVACSystemConfiguration.Configuration6 , 11 , HeatPumpType.none , HeatPumpType.non_R_744_3_stage , 822.528 , 2965.1077) ,
TestCase(BusHVACSystemConfiguration.Configuration7 , 1 , HeatPumpType.non_R_744_2_stage , HeatPumpType.non_R_744_3_stage , 428.400 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration7 , 6 , HeatPumpType.non_R_744_2_stage , HeatPumpType.non_R_744_3_stage , 856.80 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration7 , 8 , HeatPumpType.non_R_744_2_stage , HeatPumpType.non_R_744_3_stage , 822.528 , 616.1931) ,
TestCase(BusHVACSystemConfiguration.Configuration7 , 11 , HeatPumpType.non_R_744_2_stage , HeatPumpType.non_R_744_3_stage , 822.528 , 2984.8347) ,
TestCase(BusHVACSystemConfiguration.Configuration8 , 1 , HeatPumpType.none , HeatPumpType.non_R_744_3_stage , 428.400 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration8 , 6 , HeatPumpType.none , HeatPumpType.non_R_744_3_stage , 856.80 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration8 , 8 , HeatPumpType.none , HeatPumpType.non_R_744_3_stage , 822.528 , 612.7957) ,
TestCase(BusHVACSystemConfiguration.Configuration8 , 11 , HeatPumpType.none , HeatPumpType.non_R_744_3_stage , 822.528 , 2965.1077) ,
TestCase(BusHVACSystemConfiguration.Configuration9 , 1 , HeatPumpType.non_R_744_2_stage , HeatPumpType.non_R_744_3_stage , 428.400 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration9 , 6 , HeatPumpType.non_R_744_2_stage , HeatPumpType.non_R_744_3_stage , 856.80 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration9 , 8 , HeatPumpType.non_R_744_2_stage , HeatPumpType.non_R_744_3_stage , 822.528 , 616.1931) ,
TestCase(BusHVACSystemConfiguration.Configuration9 , 11 , HeatPumpType.non_R_744_2_stage , HeatPumpType.non_R_744_3_stage , 822.528 , 2984.8347) ,
TestCase(BusHVACSystemConfiguration.Configuration10 , 1 , HeatPumpType.none , HeatPumpType.non_R_744_3_stage , 428.400 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration10 , 6 , HeatPumpType.none , HeatPumpType.non_R_744_3_stage , 856.80 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration10 , 8 , HeatPumpType.none , HeatPumpType.non_R_744_3_stage , 822.528 , 612.7957) ,
TestCase(BusHVACSystemConfiguration.Configuration10 , 11 , HeatPumpType.none , HeatPumpType.non_R_744_3_stage , 822.528 , 2965.1077) ,
// only electrical heatpumps
TestCase(BusHVACSystemConfiguration.Configuration2 , 1 , HeatPumpType.non_R_744_continuous , HeatPumpType.none , 299.88 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration2 , 6 , HeatPumpType.non_R_744_continuous , HeatPumpType.none , 299.88 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration2 , 8 , HeatPumpType.non_R_744_continuous , HeatPumpType.none , 288.8324 , 0) ,
TestCase(BusHVACSystemConfiguration.Configuration2 , 11 , HeatPumpType.non_R_744_continuous , HeatPumpType.none , 1520.7 , 0) ,
TestCase(BusHVACSystemConfiguration.Configuration4 , 1 , HeatPumpType.non_R_744_continuous , HeatPumpType.none , 428.400 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration4 , 6 , HeatPumpType.non_R_744_continuous , HeatPumpType.none , 856.80 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration4 , 8 , HeatPumpType.non_R_744_continuous , HeatPumpType.none , 1413.2125 , 0) ,
TestCase(BusHVACSystemConfiguration.Configuration4 , 11 , HeatPumpType.non_R_744_continuous , HeatPumpType.none , 2647.3455 , 0) ,
TestCase(BusHVACSystemConfiguration.Configuration5 , 1 , HeatPumpType.none , HeatPumpType.non_R_744_continuous , 428.400 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration5 , 6 , HeatPumpType.none , HeatPumpType.non_R_744_continuous , 856.80 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration5 , 8 , HeatPumpType.none , HeatPumpType.non_R_744_continuous , 1413.2125 , 0) ,
TestCase(BusHVACSystemConfiguration.Configuration5 , 11 , HeatPumpType.none , HeatPumpType.non_R_744_continuous , 3636.1338 , 0) ,
TestCase(BusHVACSystemConfiguration.Configuration6 , 1 , HeatPumpType.none , HeatPumpType.non_R_744_continuous , 428.400 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration6 , 6 , HeatPumpType.none , HeatPumpType.non_R_744_continuous , 856.80 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration6 , 8 , HeatPumpType.none , HeatPumpType.non_R_744_continuous , 1413.2125 , 0) ,
TestCase(BusHVACSystemConfiguration.Configuration6 , 11 , HeatPumpType.none , HeatPumpType.non_R_744_continuous , 3636.1338 , 0) ,
TestCase(BusHVACSystemConfiguration.Configuration7 , 1 , HeatPumpType.non_R_744_continuous , HeatPumpType.non_R_744_continuous , 428.400 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration7 , 6 , HeatPumpType.non_R_744_continuous , HeatPumpType.non_R_744_continuous , 856.80 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration7 , 8 , HeatPumpType.non_R_744_continuous , HeatPumpType.non_R_744_continuous , 1413.2125 , 0) ,
TestCase(BusHVACSystemConfiguration.Configuration7 , 11 , HeatPumpType.non_R_744_continuous , HeatPumpType.non_R_744_continuous , 3636.1338 , 0) ,
TestCase(BusHVACSystemConfiguration.Configuration8 , 1 , HeatPumpType.none , HeatPumpType.non_R_744_continuous , 428.400 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration8 , 6 , HeatPumpType.none , HeatPumpType.non_R_744_continuous , 856.80 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration8 , 8 , HeatPumpType.none , HeatPumpType.non_R_744_continuous , 1413.2125 , 0) ,
TestCase(BusHVACSystemConfiguration.Configuration8 , 11 , HeatPumpType.none , HeatPumpType.non_R_744_continuous , 3636.1338 , 0) ,
TestCase(BusHVACSystemConfiguration.Configuration9 , 1 , HeatPumpType.non_R_744_continuous , HeatPumpType.non_R_744_continuous , 428.400 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration9 , 6 , HeatPumpType.non_R_744_continuous , HeatPumpType.non_R_744_continuous , 856.80 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration9 , 8 , HeatPumpType.non_R_744_continuous , HeatPumpType.non_R_744_continuous , 1413.2125 , 0) ,
TestCase(BusHVACSystemConfiguration.Configuration9 , 11 , HeatPumpType.non_R_744_continuous , HeatPumpType.non_R_744_continuous , 3636.1338 , 0) ,
TestCase(BusHVACSystemConfiguration.Configuration10 , 1 , HeatPumpType.none , HeatPumpType.non_R_744_continuous , 428.400 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration10 , 6 , HeatPumpType.none , HeatPumpType.non_R_744_continuous , 856.80 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration10 , 8 , HeatPumpType.none , HeatPumpType.non_R_744_continuous , 1413.2125 , 0) ,
TestCase(BusHVACSystemConfiguration.Configuration10 , 11 , HeatPumpType.none , HeatPumpType.non_R_744_continuous , 3636.1338 , 0) ,
// mixed electrical and mechanical heatpumps
TestCase(BusHVACSystemConfiguration.Configuration7 , 1 , HeatPumpType.non_R_744_continuous , HeatPumpType.non_R_744_3_stage , 428.400 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration7 , 6 , HeatPumpType.non_R_744_continuous , HeatPumpType.non_R_744_3_stage , 856.80 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration7 , 8 , HeatPumpType.non_R_744_continuous , HeatPumpType.non_R_744_3_stage , 883.4159 , 547.9913) ,
TestCase(BusHVACSystemConfiguration.Configuration7 , 11 , HeatPumpType.non_R_744_continuous , HeatPumpType.non_R_744_3_stage , 1116.3204 , 2644.1315) ,
TestCase(BusHVACSystemConfiguration.Configuration7 , 1 , HeatPumpType.non_R_744_2_stage , HeatPumpType.non_R_744_continuous , 428.400 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration7 , 6 , HeatPumpType.non_R_744_2_stage , HeatPumpType.non_R_744_continuous , 856.80 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration7 , 8 , HeatPumpType.non_R_744_2_stage , HeatPumpType.non_R_744_continuous , 1360.3368 , 59.7565) ,
TestCase(BusHVACSystemConfiguration.Configuration7 , 11 , HeatPumpType.non_R_744_2_stage , HeatPumpType.non_R_744_continuous , 3393.4694 , 285.6602) ,
TestCase(BusHVACSystemConfiguration.Configuration9 , 1 , HeatPumpType.non_R_744_continuous , HeatPumpType.non_R_744_3_stage , 428.400 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration9 , 6 , HeatPumpType.non_R_744_continuous , HeatPumpType.non_R_744_3_stage , 856.80 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration9 , 8 , HeatPumpType.non_R_744_continuous , HeatPumpType.non_R_744_3_stage , 883.4159 , 547.9913) ,
TestCase(BusHVACSystemConfiguration.Configuration9 , 11 , HeatPumpType.non_R_744_continuous , HeatPumpType.non_R_744_3_stage , 1116.3204 , 2644.1315) ,
TestCase(BusHVACSystemConfiguration.Configuration9 , 1 , HeatPumpType.non_R_744_2_stage , HeatPumpType.non_R_744_continuous , 428.400 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration9 , 6 , HeatPumpType.non_R_744_2_stage , HeatPumpType.non_R_744_continuous , 856.80 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration9 , 8 , HeatPumpType.non_R_744_2_stage , HeatPumpType.non_R_744_continuous , 1360.3368 , 59.7565) ,
TestCase(BusHVACSystemConfiguration.Configuration9 , 11 , HeatPumpType.non_R_744_2_stage , HeatPumpType.non_R_744_continuous , 3393.4694 , 285.6602) ,
]
public void SSMTest_Cooling_SingleEnvironment(BusHVACSystemConfiguration cfg, HeatPumpType driverHeatpump,
HeatPumpType passengerHeatpump, int envId, double expectedElPwrW, double expectedMechPwrW)
public void SSMTest_Cooling_SingleEnvironment(BusHVACSystemConfiguration cfg, int envId, HeatPumpType driverHeatpump,
HeatPumpType passengerHeatpump, double expectedElPwrW, double expectedMechPwrW)
{
var auxData = GetAuxParametersConventionalSingleDeckForTest(cfg, driverHeatpump, passengerHeatpump);
......@@ -61,28 +154,51 @@ public class SSMTestHeatingCooling
ssmInputs.EnvironmentalConditionsMap = new EnvironmentalConditionsMap(new[] { newEnv });
// ---
Assert.AreEqual(cfg, ssmInputs.HVACSystemConfiguration);
var ssm = new SSMTOOL(auxData.SSMInputsCooling);
Console.WriteLine($"{ssm.ElectricalWAdjusted.Value().ToGUIFormat(4)}, {ssm.MechanicalWBaseAdjusted.Value().ToGUIFormat(4)}");
Assert.AreEqual(expectedElPwrW, ssm.ElectricalWAdjusted.Value(), 1e-3);
Assert.AreEqual(expectedMechPwrW, ssm.MechanicalWBaseAdjusted.Value(), 1e-3);
Assert.AreEqual(expectedElPwrW, ssm.ElectricalWAdjusted.Value(), 1e-3, "expected Electric Power");
Assert.AreEqual(expectedMechPwrW, ssm.MechanicalWBaseAdjusted.Value(), 1e-3, "expected Mechanical Power");
}
[
// only mechanical heatpumps
// electric: only ventilation, mechanic: heatpump
TestCase(BusHVACSystemConfiguration.Configuration1, HeatPumpType.none, HeatPumpType.none, 293.8056, 0.0), // correct? I'd expect P_el = 293 as well! (ventilation low)
TestCase(BusHVACSystemConfiguration.Configuration2, HeatPumpType.non_R_744_2_stage, HeatPumpType.none, 293.8056, 109.29748),
TestCase(BusHVACSystemConfiguration.Configuration3, HeatPumpType.none, HeatPumpType.none, 662.12989, 0.0), // correct? I'd expect p_el = 622 as well! (ventilation high)
TestCase(BusHVACSystemConfiguration.Configuration4, HeatPumpType.non_R_744_2_stage, HeatPumpType.none, 662.12989, 398.5246),
TestCase(BusHVACSystemConfiguration.Configuration6, HeatPumpType.none, HeatPumpType.non_R_744_2_stage, 662.1298, 444.7991),
TestCase(BusHVACSystemConfiguration.Configuration1 , HeatPumpType.none , HeatPumpType.none , 295.3949 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration2 , HeatPumpType.non_R_744_2_stage , HeatPumpType.none , 295.3949 , 109.29748) ,
TestCase(BusHVACSystemConfiguration.Configuration3 , HeatPumpType.none , HeatPumpType.none , 664.4004 , 0.0) ,
TestCase(BusHVACSystemConfiguration.Configuration4 , HeatPumpType.non_R_744_2_stage , HeatPumpType.none , 664.4004 , 398.5246) ,
TestCase(BusHVACSystemConfiguration.Configuration5 , HeatPumpType.none , HeatPumpType.non_R_744_3_stage , 664.4004 , 429.8231) ,
TestCase(BusHVACSystemConfiguration.Configuration6 , HeatPumpType.none , HeatPumpType.non_R_744_3_stage , 664.4004 , 429.8231) ,
TestCase(BusHVACSystemConfiguration.Configuration7 , HeatPumpType.non_R_744_2_stage , HeatPumpType.non_R_744_3_stage , 664.4004 , 432.3237) ,
TestCase(BusHVACSystemConfiguration.Configuration8 , HeatPumpType.none , HeatPumpType.non_R_744_3_stage , 664.4004 , 429.8231) ,
TestCase(BusHVACSystemConfiguration.Configuration9 , HeatPumpType.non_R_744_2_stage , HeatPumpType.non_R_744_3_stage , 664.4004 , 432.3237) ,
TestCase(BusHVACSystemConfiguration.Configuration10 , HeatPumpType.none , HeatPumpType.non_R_744_3_stage , 664.4004 , 429.8231) ,
// only electrical heatpumps
// electric: ventilation + heatpump
//TestCase(BusHVACSystemConfiguration.Configuration1, HeatPumpType.none, HeatPumpType.none, 0, 0.0),
TestCase(BusHVACSystemConfiguration.Configuration2, HeatPumpType.non_R_744_continuous, HeatPumpType.none, 394.405, 0.0),
TestCase(BusHVACSystemConfiguration.Configuration2, HeatPumpType.non_R_744_continuous, HeatPumpType.none, 395.9945, 0.0),
//TestCase(BusHVACSystemConfiguration.Configuration3, HeatPumpType.none, HeatPumpType.none, 0.0, 0.0),
TestCase(BusHVACSystemConfiguration.Configuration4, HeatPumpType.non_R_744_continuous, HeatPumpType.none, 1031.611, 0.0),
TestCase(BusHVACSystemConfiguration.Configuration4, HeatPumpType.non_R_744_continuous, HeatPumpType.none, 1033.8823, 0.0),
TestCase(BusHVACSystemConfiguration.Configuration5 , HeatPumpType.none , HeatPumpType.non_R_744_continuous , 1076.1036 , 0) ,
TestCase(BusHVACSystemConfiguration.Configuration6 , HeatPumpType.none , HeatPumpType.non_R_744_continuous , 1076.1036 , 0) ,
TestCase(BusHVACSystemConfiguration.Configuration7 , HeatPumpType.non_R_744_continuous , HeatPumpType.non_R_744_continuous , 1076.1036 , 0) ,
TestCase(BusHVACSystemConfiguration.Configuration8 , HeatPumpType.none , HeatPumpType.non_R_744_continuous , 1076.1036 , 0) ,
TestCase(BusHVACSystemConfiguration.Configuration9 , HeatPumpType.non_R_744_continuous , HeatPumpType.non_R_744_continuous , 1076.1036 , 0) ,
TestCase(BusHVACSystemConfiguration.Configuration10 , HeatPumpType.none , HeatPumpType.non_R_744_continuous , 1076.1036 , 0) ,
// mixed electrical and mechanical heatpumps
TestCase(BusHVACSystemConfiguration.Configuration7 , HeatPumpType.non_R_744_continuous , HeatPumpType.non_R_744_3_stage , 707.0598 , 383.9348) ,
TestCase(BusHVACSystemConfiguration.Configuration7 , HeatPumpType.non_R_744_2_stage , HeatPumpType.non_R_744_continuous , 1039.7276 , 41.703) ,
TestCase(BusHVACSystemConfiguration.Configuration9 , HeatPumpType.non_R_744_continuous , HeatPumpType.non_R_744_3_stage , 707.0598 , 383.9348) ,
TestCase(BusHVACSystemConfiguration.Configuration9 , HeatPumpType.non_R_744_2_stage , HeatPumpType.non_R_744_continuous , 1039.7276 , 41.703) ,
]
public void SSMTest_Cooling_AvgAllEnvironments(BusHVACSystemConfiguration cfg, HeatPumpType driverHeatpump,
......@@ -90,10 +206,16 @@ public class SSMTestHeatingCooling
{
var auxData = GetAuxParametersConventionalSingleDeckForTest(cfg, driverHeatpump, passengerHeatpump);
var ssmInputs = auxData.SSMInputsCooling as SSMInputs;
Assert.NotNull(ssmInputs);
Assert.AreEqual(cfg, ssmInputs.HVACSystemConfiguration);
var ssm = new SSMTOOL(auxData.SSMInputsCooling);
Assert.AreEqual(expectedElPwrW, ssm.ElectricalWAdjusted.Value(), 1e-3);
Assert.AreEqual(expectedMechPwrW, ssm.MechanicalWBaseAdjusted.Value(), 1e-3);
Console.WriteLine($"{ssm.ElectricalWAdjusted.Value().ToGUIFormat(4)}, {ssm.MechanicalWBaseAdjusted.Value().ToGUIFormat(4)}");
Assert.AreEqual(expectedElPwrW, ssm.ElectricalWAdjusted.Value(), 1e-3, "expected electrical power");
Assert.AreEqual(expectedMechPwrW, ssm.MechanicalWBaseAdjusted.Value(), 1e-3, "expected mechanical power");
}
......
0% Loading or .